2 transportation guidelines, 3 storage guidelines, 3 product description – Xylem IM254R01 e-HM Series User Manual
Page 4: 1 pump design, 2 application limits, 3 the data plate, 4 installation, 2 transportation guidelines 2.3 storage guidelines

2.2 Transportation guidelines
Precautions
WARNING:
• Observe accident prevention regulations in force.
• Crush hazard. The unit and the components can be
heavy. Use proper lifting methods and wear steel-toed
shoes at all times.
Check the gross weight that is indicated on the package in order to se-
lect proper lifting equipment.
Position and fastening
The unit can be transported either horizontally or vertically. Make sure
that the unit is securely fastened during transportation, and cannot roll
or fall over.
HM122_M043_B_sc
2.3 Storage guidelines
Storage location
NOTICE:
• Protect the product against humidity, dirt, heat sources, and me-
chanical damage.
• The product must be stored at an ambient temperature from
-40°C to +60°C (-40°F to 140°F).
3 Product Description
3.1 Pump design
The pump is a multistage, non-self priming pump. The pump can be
used to pump:
• Cold water
• Warm water
Intended use
The pump is suitable for:
• Civil and industrial water distribution systems
• Irrigation (for example, agriculture and sporting facilities)
Improper use
DANGER:
Do not use this pump to handle flammable and/or explosive
liquids.
WARNING:
Improper use of the pump may create dangerous conditions
and cause personal injury and damage to property.
NOTICE:
Do not use this pump to handle liquids containing abrasive, solid, or
fibrous substances, toxic or corrosive liquids, potable liquids other than
water, or liquids not compatible with the pump construction material.
An improper use of the product leads to the loss of the warranty.
3.2 Application limits
Table 1: Pressure and temperature limits
Seal Code 1HM, 3HM
5HM
10HM,
15HM,
22HM
2-6 Stages 7+ Stages 2-5 Stages 6+ Stages All Stages
BQE
147PSI at
248F
235PSI at
248F
147PSI at
248F
235PSI at
248F
235PSI at
248F
BQV
147PSI at
248F
235PSI at
248F
147PSI at
248F
235PSI at
248F
235PSI at
248F
QQE
147PSI at
248F
235PSI at
194F
147PSI at
248F
235PSI at
194F
235PSI at
194F
QQV
147PSI at
248F
235PSI at
194F
147PSI at
248F
235PSI at
194F
235PSI at
194F
BVE
147PSI at
194F
Not Avail-
able
147PSI at
194F
Not Avail-
able
Not Avail-
able
3.3 The data plate
The data plate is a label on the pump. The data plate lists key product
specifications.
1.
Goulds Water Technology Catalog Number
2.
Capacity range
3.
TDH range
4.
Rated speed
5.
Rated horsepower
6.
Maximum operating pressure
7.
Maximum fluid temperature
8.
Pump serial number
IMQ or other marks (for electric pump only)
Unless otherwise specified, for products with a mark of electrical-relat-
ed safety approval, the approval refers exclusively to the electrical
pump.
3 Product Description
Model e-HM Installation, Operation, and Maintenance Manual
3