Xylem IM180 R3 Standard and Dual Voltage Motors User Manual
Page 12

10
CentriPro Motors Installation, Operation and Maintenance Manual
Operation (continued)
Table 5 — 6" - 10" Three Phase Resistance, KVA, Efficiency, Fuses
Motor HP kW Volts Phase F.L. KVA Line - Line
Time Delay Fuse
Order No.
Efficiency % Code
Resistance
Standard
Dual Ele.
6M058
5 3.7 200
75.9
K
0.618
50
25
6M052
5
3.7
230
76.8
K
0.806
45
20
6M054
5
3.7
460
76.8
K
3.050
25
10
6M078 7.5 5.5 200
77.9
J
0.504
80
40
6M072
7.5
5.5
230
78.5
J
0.651
70
30
6M074
7.5
5.5
460
78.5
J
2.430
35
15
6M108 10 7.5 200
79.7
K
0.315
100
50
6M102
10
7.5
230
79.3
K
0.448
90
40
6M104
10
7.5
460
79.3
K
1.619
45
20
6M158 15 11 200
81.7
K
0.213
175
70
6M152
15
11
230
81.7
K
0.312
150
60
6M154
15
11
460
81.7
K
1.074
70
30
6M208 20 15 200
82.7
J
0.189
200
90
6M202
20
15
230
83.2
J
0.258
175
70
6M204
20
15
460
3 83.2 J 0.861 90
35
6M258 25 18.5 200
82.0
K
0.146
250
110
6M252
25
18.5
230
83.0
K
0.210
225
90
6M254
25
18.5
460
83.0
K
0.666
110
45
6M308 30 22 200
82.9
J
0.119
300
125
6M302
30
22
230
82.5
K
0.166
250
100
6M304
30
22
82.5
K
0.554
125
50
6M404
40
30
84.0
H
0.446
175
70
66M504
50
37
82.5
J
0.388
225
90
86M504
50
37
84.1
H
0.331
200
90
86M604
60
45
460
84.7
H 0.278
250
110
8M754
75
55
84.9
H
0.218
300
125
8M1004 100
75
85.2
H
0.164
400
175
8M1254 125
90
84.2
G
0.132
500
225
8M1504 150 110
85.6
G
0.115
600
250
10M2004 200 150
87.2
F
0.0929
800
350