beautypg.com

Safety requirements – Bell & Gossett P86074A Booster Pumps User Manual

Page 2

background image

ELECTRICAL SAFETY

2

MECHANICAL SAFETY

WARNING: EXCESSIVE SYSTEM PRESSURE

HAZARD

The maximum working pressure of the pump is listed on

the nameplate – DO NOT EXCEED THIS PRESSURE.

Failure to follow these instructions could result in serious

personal injury, death and/or property damage.

WARNING: EXCESSIVE PRESSURE HAZARD –

VOLUMETRIC EXPANSION

The heating of water and other fluids causes volumetric

expansion. The associated forces may cause failure of sys-

tem components and the release of high temperature fluids.

This can be prevented by installing properly sized and

located compression tanks and pressure relief valves.

Failure to follow these instructions could result in serious

personal injury, death and/or property damage.

WARNING: EXTREME TEMPERATURE HAZARD

If the pump, motor including drive, or piping are oper-

ating at extremely high or low temperature, guarding or insu-

lation is required. Failure to follow these instructions could re-

sult in serious personal injury, death and/or property damage.

THERMAL SAFETY

WARNING: ELECTRICAL GROUNDING HAZARD

Adequate electrical grounding is required for the safe

operation of B&G Pumps. The use of grounded metal con-

duit assures this requirement. If the means of connection to

the supply-connection box (wiring compartment) is other

than grounded metal conduit, ground the pump back to the

service. Connect a copper conductor at least the size of the

circuit conductors supplying the pump to the grounding

screw provided within the wiring compartment. Failure to

follow these instructions could result in serious personal

injury, death and/or property damage.

WARNING: ELECTRICAL SHOCK HAZARD

Disconnect and lockout the power before servicing.

Failure to follow these instructions could result in serious

personal injury or death.

REMOVAL OF THE PUMP FROM EXISTING SYSTEM FOR REPLACEMENT

PUMP INSTALLATION

1. Close the valves on the suction and discharge sides of

the pump. If no valves have been installed, it may be nec-

essary to drain the system.

This pump is for indoor use only.

WARNING: HOT WATER HAZARD

Before draining the system, allow water to cool to

100°F max., open the drain valve (take precautions against

water damage) and leave the drain valve open until servic-

ing is complete. Failure to follow these instructions could

result in serious personal injury, death and/or property

damage.

WARNING: ELECTRICAL SHOCK HAZARD

Be certain the electrical power is not present at the

motor leads before continuing. Failure to follow these in-

structions could result in serious personal injury or death.

2. Loosen the conduit box cover screw and remove the cover.
3. Disconnect the electrical supply and control lines to the

pump

.

WARNING: HIGH PRESSURE HAZARD

Pressure may be present in the pump body. This

pressure can be relieved by loosening the flange bolts and

shifting the pump assembly slightly to allow the pressur-

ized water to escape. Failure to follow these instructions

could result in serious personal injury or death.

4. Remove the flange bolts and nuts and then remove the

pump from the piping.

WARNING: ELECTRICAL SHOCK HAZARD

Electrical connections are to be made by a qualified

electrician in accordance with all applicable codes, ordi-

nances and good practices. Failure to follow these instruc-

tions could result in serious personal injury, death and/or

property damage.

Locate the pump so there is sufficient room for inspection,

maintenance and service. Bell & Gossett recommends the

installation of service valves on the suction and discharge of

all pumps to facilitate servicing or replacement of the pump

without draining the system.
Install suction and discharge flanges on the pipe ends. The

use of teflon tape sealer or a high quality thread sealant is

recommended.
Be sure to minimize any pipe-strain on the pump. Support the

suction and discharge piping by the use of pipe hangers near

the pump. Line up the vertical and horizontal piping so that

the bolt-holes in the pump flanges match the bolt-holes in the

pipe flanges. (DO NOT ATTEMPT TO SPRING THE SUCTION

OR DISCHARGE LINES IN POSITION. THIS MAY RESULT IN

UNWANTED STRESS IN THE PUMP BODY, FLANGE CON-

NECTIONS AND PIPING.) The code for Pressure Piping

(ANSI B31.1) lists many types of supports available for various

applications.
Bell & Gossett flange gaskets must be installed between the

Series PL-VS

pump body flanges and the suction and

discharge pipe flanges. Use

7

/

16

" diameter and appropriate

length cap screws and matching nuts to connect the pump to

the flanges.

SAFETY REQUIREMENTS

WARNING: ELECTRICAL SHOCK HAZARD

After power is disconnected from the pump, high

voltage levels are maintained by the DC link capacitor.

There are no serviceable parts inside the control box. Do

not touch electrical components until the power has

been disconnected for at least 9 minutes. Failure to fol-

low these instructions could result in serious personal

injury, death and/or property damage.