SmartLIGHT User Manual Page 10

MASTER/SLAVE:

If you have more than one unit you wish to operate the same but do not have a DMX
controller or foot controller then you can do so in the following simple way: Connect a 3 pin
DMX XLR cable from the DMX OUT socket on the master unit and plug in to the DMX IN socket
on the slave device. Then set the Slave device to DMX address to be A001 and it will repeat
whatever operation is current on the master unit. This can be repeated for up to 32 fixtures.

DMX OPERATIONS:

Channel

Function

1

000-007 Closed
008-190 Dimming 0-100%
191-200 Sound to light pulse
196-200 Sound to light strobe
201-247 Strobe
248-255 Open 100%

SmartLIGHT User Manual Page 3

PACKAGE CONTENTS:

Please check the contents to ensure that the product has been received in good
condition.

SmartLIGHT Box:

SmartLIGHT Unit x 1pcs

User’s Guide x 1pcs

Power Cord x 2pcs (EU and UK)

Mounting brackets x 2pcs



If you find any accessory is missing or the product has arrived with any problems,
please contact your local dealer at once. Do not try to fix this item yourself or you
will lose the warranty. Please keep the original package and invoice for any possible
replacement or returned demand.

INSTALLATION:


Every person involved with the installation, operation and maintenance of this device
should be qualified and follow the instructions in this User Guide. We recommend
that this product should be used within the guidelines of “HSG95”. When you connect
to the main power supply the device will take a few seconds before ready for use.

MOUNTING INSTRUCTIONS:


The mounting brackets are already attached to the product when you open the box
but you can adjust them giving more clearance. You can use them as floor standing
or you can fix a G-Clamp to the bracket securely ready for mounting. After finding
the desired position tighten the G-Clamp and use a safety wire the security loop for
extra security.

When selecting an installation location, take into consideration routine maintenance.
Safety cables must always be used. Never mount in places where the fixture will be
exposed to rain, high humidity, extreme temperatures changes or restricted
ventilation.