Operational checks, After checking procedures – Armasight NSGNYX7001QGDI1 Nyx7 GEN 2+ QS Night Vision Goggles User Manual
Page 25

25
SEq NO.
LOCATION ITEM TO
CHECK/SERVICE
PROCEDURE
NOT FULLY MISSION
CAPABLE IF...
4
Lens Cap
Inspect for cracked, torn, or missing lens caps.
Cap is torn or cut.
Cup is not secured to the housing
of the lens.
5
Eyecups
Inspect for dirt or dust. Inspect for cracked, torn, bent,
broken or improperly fitted eyecup.
If necessary, clean as per Part 4.4.2.
Cup is torn or cut.
6
Battery
Compartment/ Cap
Inspect for corrosion, moisture, corroded or defective
contacts. Verify that the o-ring is present.
Contacts are damaged or corroded,
or the o-ring is missing.
7
Lenses
Inspect optical surfaces for dirt, fingerprint residue,
scratches, chips, or cracks.
Scratches or chips hinder vision
when the Nyx-7 is turned on. Cracks
are present.
8
Focusing Ring
Rotate the focusing ring to ensure free movement (range
is approximately 1/3 turn).
Ring gets stuck or adversely affects
the user’s ability to properly focus
the unit.
9
Eyepiece Rings
Rotate the eyepiece rings to make sure the eyepiece is not
too tight or too loose. Range is approximately ½ turn.
Ring gets stuck, is too loose, or ad-
versely affects the user’s ability to
properly adjust the diopter.
10
Goggle Kit
Check the straps and pads for cuts tears, fraying, holes,
cracks or defective fasteners.
Check the mount of goggle kit for dirt, dust or corrosion.
Insert goggle rail into guide to verify secure attachment
of goggle to head mount. If necessary, clean the mount
with water.
Press the buttons of the mount and check for free motion.
Inspect for damage.
11
Optional Equip-
ment
Inspect optional items for dirt, or corrosion, damage, and
missing parts. Check for proper operation.
If necessary, clean as detailed in Part 4.4.2.
Equipment is damaged or parts are
missing.
OPERATIONAL CHECKS
CAUTION:
Do not activate the Nyx-7 in daylight unless the lens cap is on, or you are operating under dark conditions.
NOTE:
Daylight checks are described below.
12
Operating
Button
Install the battery. Push the button by short press. Look
for the green glow in eyepieces (it should appear after a
slight delay).
Image is present.
Push the button button by long press for activate the
buily-in IR illuminator. Look for a permanent red glow in
the eyepiece viewing area.
Permanent red glow is absent
13
Viewed Image
Inspect for any operational defects (refer to Part 4.3: Iden-
tification of Operational Defects).
Shading, edge glow, flashing, flick-
ering, and intermittent operation,
or excessive cosmetic defects are
found.
AFTER CHECKING PROCEDURES
14
Turn the unit OFF. Verify that the green glow fades from
the eyepieces.
Remove the battery.
Return the unit and all accessories to the soft carrying
case.
TABLE 4-1. CONTINUED