5. MAInTEnAnCE PROCEDURES
The WWZ Scope should always be stored in the supplied packaging, particularly in heated and venti-
lated rooms. To keep the device operational, please follow the instructions (below) regarding prepa-
rations preparations for storage. The battery should be stored separately from the device, and be
inserted into the battery compartment only when the device is being prepared for use. The presence
of both acids and alkalis near the device is not recommended.
While stored, your WWZ Scope should be protected from exposure to direct sunlight or extreme tem-
peratures.
wwZ SCOPE ClEAnIng PROCEDURES
1) Gently remove any dirt from the sight’s body using a clean, soft cloth.
2) Wipe external surfaces down (with the exception of optical surfaces) with a clean cloth that has
been moistened with pure water.
3) Dry all wet surfaces with a different clean, dry cloth.
4) Carefully remove any dirt from the optical surfaces using a lens brush.
5) To avoid scratches, optical surfaces must be cleaned using a clean cotton swab that has been slight-
ly dampened with pure alcohol. The glass should be wiped in circular motions starting from the center
and moving out towards the edge, without touching the barrel. Change the cotton swab as soon as it
becomes dirty.
EyEPIECE MAInTEnAnCE
Occasionally, you may have to clean the eyepiece of your Armasight WWZ Scope sight. After unpacking
the WWZ Scope sight, make sure that there is no dust or dirt on or in the eyepiece. If you do find dust
or dirt on the eyepiece, you will need to remove them for cleaning. The body of eyepiece has two set
screws, which you will need to loosen first. After loosening these screws, turn the eyepiece counter-
clockwise to separate it from the body of the device.
nOTE:
It is unnecessary to completely remove the set screws. To avoid losing these miniature screws,
leave them at least partially inside the body of the device.
CAUTIOn:
Only apply photographic lens cleaning tissues to the surface of the eyepieces. Avoid damaging
or leaving fingerprints on the lenses. A can of compressed air may be used to blow dust off of the
lenses. Do not tip the can while spraying, as you may cause the propellant to freeze as it exits the
can. This may damage the glass and the tube phosphor screen.
PREPARATIOnS FOR STORAgE
When preparing your WWZ Scope for storage, perform the following steps:
1) Verify that the sights are operating in accordance with all previously specified procedures.
2) Remove the batteries from the battery compartments.
3) Clean the sights and all accessories.
4) Place all components into the storage case.