Ir illuminator, Windage and elevation adjustment, Ir illuminator installation – Armasight NWWWWZ000411I11 WWZ 4x GEN 1+ Night Vision Rifle Scope User Manual
Page 7: Ir illuminator operation
7
wInDAgE AnD ElEVATIOn ADjUSTMEnT
The vertical and horizontal adjustments of the Armasight
WWZ Scope can be regulated by adjusting the elevation and
windage turrets. You will first need to remove the dust caps.
Each click indicates 3/4 of an inch at 100 yard’s distance.
Once the turrets stop turning, do not attempt to turn them
any further, as this may damage the mechanism.
4. IR IllUMInATOR
Infrared illuminators are used in areas where the level of light is not sufficient for the unit to generate
a bright, clear image. An IR illuminator provides infrared light which, although invisible to the naked
eye, can greatly enhance the performance of night vision devices. Turn on the IR810 when working in
total darkness. Remember that the beam emitted by your IR illuminator will lose its brightness over
long distances.
IR IllUMInATOR InSTAllATIOn
The IR810 is a removable infrared illuminator that can be installed on the rail of the WWZ Scope. To
install the IR illuminator on your sight, perform the following steps:
1) Loosen the fixing screw on the IR810 mount.
2) Place the IR810 on the Picatinny rail.
3) Tighten the fixing screw.
IR IllUMInATOR OPERATIOn
The Armasight IR810 runs on a single CR123A battery. To install the battery, unscrew the battery com-
partment cap and insert the battery in accordance with the polarity markings on the unit’s body. Screw
the battery compartment cap back into position.
To turn the IR810 on, rotate the operation switch from the
OFF position.
To adjust the power and brightness of the beam emitted by
the IR810, rotate the illuminator operation switch.
Focus the IR beam to change the field of coverage. To fo-
cus the beam, rotate the IR illuminator lens until the image
becomes clear.
Adjust the IR spot position in the field of view of the NVD
(night vision device) as follows:
1) Loosen the screw of the clamp on the IR illuminator
mount.
2) Turn on the sight and the IR illuminator.
3) Carefully move the lens of the IR810 up and down and side to side. While looking through the eye-
pieces of your device, observe the IR spot position.
4) Once the IR spot is centered in the field of view, tighten the fixing screw of the clamp.
windage
elevatiOn
FOcuS adjuStment
Fixing Screw
battery cOmpartment
OperatiOn Switch
Screw OF clamp
beam directiOn
adjuStment