beautypg.com

Asus k8v motherboard 3-19, Select the replacement drive. press

Page 89

background image

ASUS K8V motherboard

3-19

FastBuild (tm) Utility 2.00 (c) 2002-2005 Promise Technology, Inc.

[ Select Drive for Rebuild ]

[ View Array Definition Menu ]

Array No RAID Mode Total Drv

Status

Array 1

Mirror/Stripe

4

Critical

Stripe Block:

Not Available

Gigabyte Boundary:

ON

Channel: ID

Drive Model

Capacity (MB)

3:Mas FUJITSU MPD3043AT

4325

[ Keys Available ]

[ ] Up [ ] Down [ESC] Exit [Enter] Select

[ ] Up [ ] Down [ESC] Exit [Enter] Select

7. Select the replacement drive. Press .

FastBuild (tm) Utility 2.00 (c) 2002-2005 Promise Technology, Inc.

[ Keys Available ]

[ ] Up [ ] Down [ESC] Exit [Enter] Select

[ Rebuild Array Menu ]

Array No RAID Mode Total Drv Capacity Status

Array 1 Mirror/Stripe 4 7999 Critical

Array 2 ----- ----- ----- -----
Array 3 ----- ----- ----- -----
Array 4 ----- ----- ----- -----

8. Confirm the command to copy data from the intact source hard disk onto a new

replacement hard disk. A progress gauge displays the copy progress for the
duration of the task.

9. After the rebuild process is complete, the user is prompted to reboot the

system.

Controller Configuration (6): This command shows the default for Controller
Configuration. The default value is [Enabled].