beautypg.com

5 checking the drives for data consistency, Checking the drives for data consistency -17, Using the check consistency command – Asus RS520-E6/RS8 User Manual

Page 111

background image

ASUS RS520-E6/RS8

6-17

3. After selecting the drive to rebuild, press . When prompted, press

to rebuild the drive.

4. When rebuild is complete, press any key to continue.

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A

REBUILD - PHYSICAL DRIVES SELECTION MENU

PORT #

ONLIN A00-00

RBLD A00-01

0
1

Rebuilding Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)?

LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008

BIOS Version A.08.09161344R

SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives

6.2.5

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual

drive. The utility can automatically detect and/or detect and correct any differences in

data redundancy depending on the selected option in the Objects > Adapter menu.

The Check Consistency command is available only for virtual drives included

in a RAID 1 or RAID 10 set.

Using the Check Consistency Command

To check data consistency using the Check Consistency command
1. From the Management Menu, select Check Consistency, and then press

.

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

CC Of VD(s)

LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008

BIOS Version A.08.09161344R

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option