GC EUROPE Kalore User Manual
Page 33
![background image](/manuals/295858/33/background.png)
33
GC Kalore technical manual
note :
1. material should be placed and light cured in layers. For
maximum layer thickness, please consult above table.
2. lower light intensity may cause insufficient curing or discoloration
of the material.
7. Finishing and Polishing
Finish and polish using diamond burs, polishing points and discs. to
obtain a high gloss, polishing pastes can be used.
SHADES
26 Shades
15 Universal Shades (color code on unitip cap / syringe label:
green)
XBW (Extra Bleaching White), BW (Bleaching White), A1, A2, A3,
A3.5, A4, B1, B2, B3, C2, C3, D2, CV (B5:Cervical), CVD (B7:Cervical
Dark)
5 Opaque Shades (color code on unitip cap / syringe label: violet)
AO2, AO3, AO4, OBW (Opaque Bleaching White), OXBW (Opaque
Extra Bleaching White)
6 Translucent Shades (color code on unitip cap / syringe label:
gray)
WT (White translucent), DT (Dark translucent), CT (Clear translucent),
nt (natural translucent), Gt (Gray translucent), cVt (cervical
translucent)
Note : A, B, C, D shades are based on Vita®† Shade.
STORAGE
Store in a cool and dark place (4-25°C / 39.2-77.0°F) away from high
temperatures or direct sunlight.
(Shelf life : 3 years from date of manufacture)
PACKAGES
i. unitips
1. Refill
a. Pack of 20 tips (each in 11 shades) (0.16ml per tip)
A1, A2, A3, A3.5, A4, B1, B2, B3, C2, C3, D2
b. Pack of 10 tips (each in 15 shades) (0.16mL per tip)
XBW, BW, CV, CVD, AO2, AO3, AO4, OBW, OXBW, WT,
Dt, ct, nt, Gt, cVt
Note : Weight per Unitip : 0.3g
2. Option
a. Shade guide
b. Mixing pad (No.14B)
II . Syringes
1. Refill
1 syringe (in 26 shades) (2.0ml per syringe)
Note : Weight per syringe : 4g
2. Option
a. Shade guide
b. Mixing pad (No.14B)
CAUTION
1. in case of contact with oral tissue or skin, remove immediately
with cotton or a sponge soaked in alcohol. Flush with water. to
avoid contact, a rubber dam and/or cocoa butter can be used
to isolate the operation field from the skin or oral tissue.
2. in case of contact with eyes, flush immediately with water and
seek medical attention.
3. take care to avoid ingestion of the material.
4. Wear plastic or rubber gloves during operation to avoid
direct contact with air inhibited resin layers in order to
prevent possible sensitivity.
5. For infection control reasons, Unitips are for single use only.
6. Wear protective eye glasses during light curing.
7. When polishing the polymerized material, use a dust collector
and wear a dust mask to avoid inhalation of cutting dust.
8. Do not mix with other similar products.
9. Avoid getting material on clothing.
10. in case of contact with unintended areas of tooth or prosthetic
appliances, remove with instrument, sponge, or cotton pellet
before light curing.
11. Do not use KalORe in combination with eugenol containing
materials as eugenol may hinder KalORe from setting.
Last revised: 5/2009
CE0086
MANUFACTURED BY
GC DENTAL PRODUCTS CORP.
2-285 Toriimatsu-cho, Kasugai, Aichi 486-0844, Japan
DISTRIBUTED BY
Gc cORPORatiOn
76-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8585, Japan
Gc euROPe n.V.
Researchpark Haasrode-Leuven 1240, Interleuvenlaan 33, B-3001
Leuven, Belgium
TEL: +32. 16. 74. 10. 00
Gc ameRica inc.
3737 West 127th Street, Alsip, IL 60803 U.S.A.
TEL: +1-708-597-0900.
GC ASIA DENTAL PTE. LTD.
19 Loyang Way, #06-27 Singapore 508724
TEL: +65 6546 7588