6 batch mode, 7 out of range, Batch mode – SCANTECH ID (Champtek company) V-1040BT User Manual
Page 18: Out of range
10
3.3.6
Batch Mode
This batch mode is enabled when you have scanned “Batch
Mode on”. The scanned data is stored in the memory of the
V-1040BT scanner instead of being transmitted. You can
delete the last scanned bar code data by scanning “Delete
Last Data” bar code. This function is disabled when you
scan “Batch Mode OFF”.
When scan bar code “Batch Data Output”, the stored
scanned data will be immediately transmitted to the host.
When scan barcode “Batch Data Clear”, all stored scanned
data will be erased from memory.
The capacity of this memory depends on the scanned data.
The memory size is approximately 30,000 sets of EAN13 bar
code type.
3.3.7
Out of Range
When “Out of Range” function is enabled, and the scanner
is working at out of transmission range, the scanned data
will be stored to out-of-range memory. Memory size is
approximately 25,000 sets of EAN13 bar code type.
The all stored data will be transmitted to device when
the link is reconnected, and the all data store in out-
of-range memory will be erased.