Billet Specialties Billet Bolt-On Reservoir User Manual
Billet Specialties For the car
500 Shawmut Avenue • La Grange, Illinois 60526 • Tech Line 708/588-0505 • Fax 708/588-7181
Re
v.
11
/12
Tools Needed;
1” open end wrench or adjustable wrench
1/2” open end wrench
1” deep socket
7/8” deep socket
1/4” allen wrench
9/64” allen wrench
Loc-Tite Blue Threadlocker
This kit fits the following applications;
-Small Block Chevrolet Tru Trac and V-Trac
-Big Block Chevrolet Tru Trac and V-Trac
P/N 77930/BLK77930 Power Steering Reservoir
Re-install the upper pressure nipple at this time.
Tighten firmly.
Install pump and reservoir onto the
Tru Trac or V Trac system bracket with
the 5/16”X3” allen bolts and loc washers.
Install power steering lines, fill system with
fluid and bleed.
For pumps that have a RP1300 flow control
valve installed, install spring first followed by
the plunger - screen side down before the
RP1300.
At this time remove the 5/16” installation nut
and discard. Set the 5/16” allen bolt aside for
later use.
Install the -6 AN nipple fitting with o-ring into
the back cover and tighten firmly.
Place the reservoir back cover onto the reservoir.
Apply Blue Loc-Tite to the threads of the
ten 8-32 cap screws and install through
the cover and into reservoir.
Tighten firmly.
Starting at the top, install o-ring as shown
by pressing o-ring straight down directly
into groove.
Re-install o-ring if there is any additional
slack.
O-ring should seat into groove without any
extra length hanging out.
5/16 allen bolt supplied with Tru Trac or v Trac kit
Carefully place reservoir onto pump, thread the 5/16”
bolt through the reservoir and pump. Install the 5/16”
installation nut and finger tighten.
Thread the hex bolt with o-ring installed through
reservoir and into adapter fitting on pump.
Tighten installation nut at this point.
Finish by firmly tightening hex bolt locking the
reservoir into place.
REMOVE
INSTALL
Remove the upper pressure nipple and set aside.
Remove the threaded supply nipple,
o-ring and washer.
Select the correct size threaded supply
nut. Install with o-ring and washer.
Tighten firmly.
For kits with the RP1300 flow control valve installed,
Remove the RP1300, plunger and spring. Set aside.