3.5 Reset/Reboot/Quit
Entering no. 5, Parani100 RESET, in the main menu, restores all factory Default value settings.
REBOOT restarts Parani100 for new configuration application.
QUIT instantly aborts current processing.
4. Configuration
Once users are finished configuring network settings using serial console. Users need to select
the operation mode of Parani100. Following three (3) ways can be used for selection of
operation mode:
1. Via Parani100 configuration software
2. Via Telnet (Control port)
3. Via Web browser (Internet Explorer, etc.)
In this chapter, a guide on usage of the Parani100 configuration software will be introduced.
How to configure via Telnet or Web browser will be introduced in the Appendix.
4.1 Configuration via Parani100 software
4.1.1 When Parani100 is connected to PC directly
If users are going to connect Host PC and Parani100 directly using a crossed cable, network
settings as in the chapter 3.1 will not be required.
Parani100 has factory settings: Static IP 192.168.1.10
For communication with Parani100, set the IP of Host PC to have proper address.
If you connected Parani100 to the Network, not to the Host PC, skip this chapter and go to
next chapter 4.1.2.
Open your Network Connections and see Property information of Local Network.
Change your IP address to Static:
IP: 192.168.1.11
Subnet: 255.255.255.0