Figure 3.8 Wiring for On/Com/Off port switching using momentary or
paddle switches

3.6 Wiring for Remote Con-
trol using Manual Switching

The

R.S.V.P. can also be config-

ured to accommodate manual
switching. In order to do this, you
will need two normally-open mo-
mentary switches (available at
your local electrical supply store).*
One switch will provide the signal
to turn the unit on, while the other
will provide the signal to turn the
unit off. The momentary switches

can be connected in parallel, al-
lowing your amps to be controlled
from various locations: front of
house, backstage, lighting booth,
etc. The momentary switch con-
nects to the

R.S.V.P. via the “On/

Com/Off” barrier block input on the
left panel (See Figure 3.8). Runs of
up to 2,000 feet (609.6 meters) can
be handled for connecting to
manual switches. This gives you
control over your system from just
about anywhere in a typical facility.

*Optionally, you may also choose to use a standard “paddle” switch to
control your R.S.V.P. unit.