beautypg.com

Page 10 – Crown Audio PIP-BLU Module User Manual

Page 10

background image

Networked PIP Series

Reference Manual

page 10

Connect the PIP-USP4-CN module to the amplifier
(Note: These PIP cards only works with CTs 2-Channel

models).
1. Turn the PIP module upside down so the ribbon

cable connectors located along the back edge on the

underside of the module can be clearly seen.

2. Add the supplied ribbon cable ferrite core to the end

of the (B) cable.

3. Attach the ribbon cables from the amplifier to the

ribbon-cable connectors. The 20 pin cable (A) should

connect to the connector further inside and away

from the corner (AJ9) and the 18 pin cable should

connect to the one closest to the corner (BJ5). Start

by connecting cable B.

Important: Be careful when attaching the ribbon cable

to the connector. Don’t pull cables out if they are short.

Applying pressure to an improperly seated connector could

cause the keying tabs, which ensure proper pin alignment,

to break. Connecting the ribbon cables with improper pin

alignment will likely result in damage to the PIP module.

4. Set amplifier sensitivity to 26dB, by placing both

sensitivity switches in the center position.

5. The Bridge-Mono Mode is set via software, leave the

Mode switch in Dual and set the attenuator knobs to

full clockwise, wide open, for all the features of the

USP4 to function correctly.

Mount the PIP module in the amplifier
1. With both cables firmly attached, turn the PIP to an

upright position. Verify that the cables run untwisted

between the amplifier and the PIP module. For best

fit, bend the cables up and roll in the cores between

the two circuit boards of the PIP module.

2. Insert the PIP module into the amplifier while taking

care not to crimp, pinch or stretch the ribbon cables.

3. Fasten the PIP module to the amplifier rear panel with

the two supplied mounting screws. Be sure to use the

supplied star-washers for a good ground connection.