Installation
Install the connecting tubes: Place a compression nut
and ferrule on one end of the connection tube. Push the
tube into the inlet of the spout tee. Tighten the compression
nut. Place another compression nut and ferrule on the other
end of the compression tube. Push the tube into the outlet
port of the valve. Tighten the compression nut. Repeat with
the second connection tube.
Install the rough: Remove the
plaster shields, escutcheon adapt-
ers, o-rings, and stop rings from the
valves.
Remove the plaster shield, spout
adapter, and spout adapter gasket
from the spout tee. If the mounting
surface is unusually, thin, leave
the white plastic spacer in place.
Otherwise, it may be removed and
discarded.
If necessary, reinstall the o-rings to
the corresponding grooves on the
escutcheon adapters.
Insert the valves and spout tee through the corresponding holes in the mounting surface.
Install the stop rings and escutcheon adapters. When installed properly, the stop rings will
stop the escutcheon adapters at the proper mounting height.
Lower the valves so that the escutcheon adapters rest on the mounting surface.
Slide the spout adapter gasket over the spout tee, aliging the hole in the gasket with the re-
taining pin hole on the mounting surface. Install the spout adapter. The pin on the adapter
should go through the hole in the mounting surface.
Tighten the mounting nuts and tensioning screws.
Reinstall the plaster shields. Leave them in place until
the trim is to be installed.