Installation Instructions

®

98/99

Series Rim Exit Device

This product is covered by the
following patent numbers:

3,767,238 4,427,223
3,854,763 4,466,643
4,167,280 4,741,563

911373_00(4) Copyright © 2005 Ingersoll-Rand. All rights reserved.

Devices covered by these instructions:

98/99 Rim Exit Device

98/99-F (Fire) Rim Exit Device

CD98/CD99 (Cylinder Dogging) Rim Exit Device

98-2/99-2 (Double Cylinder) Rim Exit Device

EL98/EL99 (Electric Latch Retraction) Rim Exit Device

Index:

• Screw chart ................................... 2
• Preparation chart ......................... 3
• Device installation ...................4-5
• Optional equipment ................ 6-7
• Cut device ..................................... 8
• 499F strike installation ............... 8

Special tools needed:

5/64” hex wrench
#10-24 tap
5/8” spade drill (

99-F wood door

)

Drill bits: #25, 1/8”, 1/4”,

5/16”, 3/8”, 13/32”

8

9

2

Tape and mark area being cut.

911373-00

CUT DEVICE

Cut device square

and remove all

burrs

1-1/2” minimum clearance

(with endcap removed)

Device aligned

with mounting

holes

3

Cut device square.

NOTE: Device must

be cut square for

proper end cap fit

4

Slide anti-rattle clip into device

.

Tape

Cover plate

(flush to pushbar)

Pushbar

Remove anti-rattle clip

1

Measure amount to cut off device.

Anti-rattle

clip

2”

Minimum

499F STRIKE INSTALLATION

Prepare and install screws
through 2 strike slots.

1

3

4

#25 Drill

#10-24 tap

2 places

CL

Roller

(against door)

CL

Install strike hook and
additional strike screws.

2

Template aligns as shown.

3

1/16”

Strike

hook

If using a mullion, holes
may be predrilled

CL

Template

(align on C and

against strike)

L

If 5/8” diameter wire access hole

has been predrilled in door, cut

device 5/16” from center of hole.

Note

5/16”

Please give these instructions to building owner after device is installed

#25 Drill

#10-24 tap

2 places

Metal

W

ood

13/32” Drill

thru for

sex bolts

2 places

#25 Drill

#10-24 tap

3 places

This manual is related to the following products: