beautypg.com

Dexter Laundry T-1200 (30-Cycle) User Manual

Page 16

background image

16

will turn off and the hot and the cold water valves to the tub will turn on

until the low water level is reached or for 30 seconds, whichever comes first.

Then the drain will open and proceed to the next step after the “open drain”

step is completed.

If advancing before a chemical injection of the bath, the drain will open

immediately and the cycle will proceed to the next step when the “open drain”

step is completed.

If advancing during a spin, the tumbler will begin to decelerate immediately.

However the cycle may proceed to the next bath before the tumbler comes to a

complete stop. The cycle cannot be advanced further while the tumbler is

decelerating.

If a temperature PCB is installed in the I/O PCB and the temperature programmed

from 20 to 90 (Celsius), advancing will turn off the heater relay or steam

valve immediately, if either is on, and open the drain after a three second

delay. If the display shows a water temperature from 65 to 90 (may be

displayed by pressing the “DOWN” and “START” buttons together), the drain will

close again when the washer indicates empty and the hot and the cold water

valves to the tub will turn on until the low water level is reached. The cycle

will then continue to the next bath, or if programmed, to the spin of the

current bath.

To exit the Rapid Advance mode during the cycle, turn the key to Run. The

cycle will continue normally.

Notes:

• The cycle cannot be advanced during the “open drain” step of the bathes.
• The cycle cannot be advanced when the hot and cold water valves to the tub

are on after advancing during or after a chemical injection.
• The cycle cannot be advanced again while the hot and cold water valves to the

tub are on after advancing when the water temperature was 65 to 90.
• The Rapid Advance mode may only be entered after a cycle is started.
• The indicator lights will show to which segment the cycle has been advanced.
• The Rapid Advance mode cannot skip the final three tumbles of the cycle. The

door lock may remain activated for a couple minutes after the cycle has been

completed.
• The chemical injection signals will not turn on if the Rapid Advance mode is

entered before the injection.

To end the cycle without waiting for the time to count down, push and hold the

“STOP” button for 5 seconds or more. The display will then show the cycle

number and be ready to start the cycle.