Dexter Laundry T-1200 (30-Cycle) User Manual
Page 16
16
will turn off and the hot and the cold water valves to the tub will turn on
until the low water level is reached or for 30 seconds, whichever comes first.
Then the drain will open and proceed to the next step after the “open drain”
step is completed.
If advancing before a chemical injection of the bath, the drain will open
immediately and the cycle will proceed to the next step when the “open drain”
step is completed.
If advancing during a spin, the tumbler will begin to decelerate immediately.
However the cycle may proceed to the next bath before the tumbler comes to a
complete stop. The cycle cannot be advanced further while the tumbler is
decelerating.
If a temperature PCB is installed in the I/O PCB and the temperature programmed
from 20 to 90 (Celsius), advancing will turn off the heater relay or steam
valve immediately, if either is on, and open the drain after a three second
delay. If the display shows a water temperature from 65 to 90 (may be
displayed by pressing the “DOWN” and “START” buttons together), the drain will
close again when the washer indicates empty and the hot and the cold water
valves to the tub will turn on until the low water level is reached. The cycle
will then continue to the next bath, or if programmed, to the spin of the
current bath.
To exit the Rapid Advance mode during the cycle, turn the key to Run. The
cycle will continue normally.
Notes:
• The cycle cannot be advanced during the “open drain” step of the bathes.
• The cycle cannot be advanced when the hot and cold water valves to the tub
are on after advancing during or after a chemical injection.
• The cycle cannot be advanced again while the hot and cold water valves to the
tub are on after advancing when the water temperature was 65 to 90.
• The Rapid Advance mode may only be entered after a cycle is started.
• The indicator lights will show to which segment the cycle has been advanced.
• The Rapid Advance mode cannot skip the final three tumbles of the cycle. The
door lock may remain activated for a couple minutes after the cycle has been
completed.
• The chemical injection signals will not turn on if the Rapid Advance mode is
entered before the injection.
To end the cycle without waiting for the time to count down, push and hold the
“STOP” button for 5 seconds or more. The display will then show the cycle
number and be ready to start the cycle.