Dexter Laundry T-1200 (30-Cycle) User Manual
Page 11
11
END OF CYCLE
At the end of the cycle, the machine stops, the END CYCLE LED lights, the alarm
sounds, and the loading door unlocks allowing unloading of the machine.
SAFETY DOOR LOCK
This machine is equipped with a safety door lock, which prevents opening the
door if power is interrupted, until it is safe to do so.
If power failure occurs, it will be necessary to wait 2 to 3 minutes before the
door can be opened.
MOTOR DRIVE INDICATORS
There is a five digit, seven segment, display on the drive which can be viewed
by removing the access cover at the top rear of the washer. There are also
small L.E.D.s on the left and below the display that can be viewed and used for
troubleshooting. The five seven segment digits will change value depending on
where the washer is during the wash cycle.
COMPUTER CONTROL CYCLE DESCRIPTION
The T1200 computer control OPL machine has 30 different selectable cycles; 29
of the 30 cycles are preset with the most common industry applications. See
the Preset Cycle Information sheets for complete cycle information. If these
cycle settings do not meet the required application, each cycle is
reprogrammable by the user simply and reliably.
Each cycle has up to 9 baths which are Flush, Prewash, Wash, Rinse 1, 2, 3, 4,
5 and Final Rinse/Extract. There are five user selectable settings within each
bath
to allow cycle tailoring to meet exact applications. The settings and the
limits of each are shown in the table below. The Scroll Up/Scroll Down buttons
are used to change the settings.
FIGURE 9 - BATH SETTING LIMITS
Settings for
each bath
Setting Limits
Description
Cycle Time
0 to 30 minutes
(1 min. increments)
The Cycle time (tumble) settings are 0 min. to 30 min. in 1 min. increments for each bath. If
the setting is 0, then that bath is skipped over. For the Final Rinse /Extract bath, the
minimum time must be 1 min.
Water
Temp.
HOT, WARM,
COLD and NO
WATER
The water temperature setting is displayed as HH = hot, CH = warm, CC = cold and EE = No
water bath. When the No Water bath is selected, the water level can be set to either high or low
and NO Injection will be made even if the injection source is programmed.
Water
Level
HIGH or LOW
The water level setting is displayed as HI for High level and LO for low level.
Injection
Source
0 to 6
The injection source settings are 0 through 6 with 0 being no injection and settings 1 through
6 relating to an injection source. See Recommended Injection Table.
Spin Time
0 to 10 minutes
(1 min. increments)
The spin time settings are 0 min. to 10 min. in 1 min. increments. If the setting is 0, there
is no spin for the bath. Final Rinse/Extract minimum setting is 1 min.