END OF CYCLE

At the end of the cycle, the machine stops, the END CYCLE LED lights, the alarm

sounds, and the loading door unlocks allowing unloading of the machine.

SAFETY DOOR LOCK

This machine is equipped with a safety door lock, which prevents opening the

door if power is interrupted, until it is safe to do so.

If power failure occurs, it will be necessary to wait 2 to 3 minutes before the

door can be opened.

MOTOR DRIVE INDICATORS

There is a five digit, seven segment, display on the drive which can be viewed

by removing the access cover at the top rear of the washer. There are also

small L.E.D.s on the left and below the display that can be viewed and used for

troubleshooting. The five seven segment digits will change value depending on

where the washer is during the wash cycle.

COMPUTER CONTROL CYCLE DESCRIPTION

The T1200 computer control OPL machine has 30 different selectable cycles; 29

of the 30 cycles are preset with the most common industry applications. See

the Preset Cycle Information sheets for complete cycle information. If these

cycle settings do not meet the required application, each cycle is

reprogrammable by the user simply and reliably.

Each cycle has up to 9 baths which are Flush, Prewash, Wash, Rinse 1, 2, 3, 4,

5 and Final Rinse/Extract. There are five user selectable settings within each

bath

to allow cycle tailoring to meet exact applications. The settings and the

limits of each are shown in the table below. The Scroll Up/Scroll Down buttons

are used to change the settings.

FIGURE 9 - BATH SETTING LIMITS


Settings for

each bath


Setting Limits


Description


Cycle Time


0 to 30 minutes

(1 min. increments)


The Cycle time (tumble) settings are 0 min. to 30 min. in 1 min. increments for each bath. If

the setting is 0, then that bath is skipped over. For the Final Rinse /Extract bath, the

minimum time must be 1 min.


Water

Temp.


HOT, WARM,

COLD and NO

WATER


The water temperature setting is displayed as HH = hot, CH = warm, CC = cold and EE = No

water bath. When the No Water bath is selected, the water level can be set to either high or low

and NO Injection will be made even if the injection source is programmed.


Water

Level


HIGH or LOW


The water level setting is displayed as HI for High level and LO for low level.


Injection

Source


0 to 6


The injection source settings are 0 through 6 with 0 being no injection and settings 1 through

6 relating to an injection source. See Recommended Injection Table.


Spin Time


0 to 10 minutes

(1 min. increments)


The spin time settings are 0 min. to 10 min. in 1 min. increments. If the setting is 0, there

is no spin for the bath. Final Rinse/Extract minimum setting is 1 min.