Dexter Laundry T-1450 EXPRESS (30-Cycle) User Manual
Page 16

16
•
Step 12 - Intermediate spin.
The I/O interface outputs labeled Reverse and Speed1 will be active
(the two RED LED’s will light).
•
Step 13 - Full speed spin.
The I/O interface outputs labeled Reverse, Speed1 and Speed2 will be
active (the three RED LED’s will light).
DO NOT USE STEP 14 IF YOU HAVE CUSTOMIZED CYCLES PROGRAMMED, AS
THIS WILL SET THE CYCLES BACK TO THE FACTORY PRESETS.
•
Step 14 - Preset Cycles. Push START and hold, then push SCROLL UP. This
will reset the DEXTER preset cycles back to the factory settings.
At cycle complete, switch the Advance/Run/Program switch to the Run position,
and the unit is ready to select a run cycle.
RAPID ADVANCE MODE
To enter the Rapid Advance mode, insert the key into the Rapid
Advance/Run/Program lock and turn the key counter-clockwise (CCW). The Rapid
Advance mode must be entered during the cycle. If the cycle has not yet
started, press the “DOWN” button or the “UP” button to choose a cycle and then
the “START” button to begin the cycle.
To advance to the next step in the cycle, push both the “UP” and “START”
buttons at the same time. The display will show “Ad” (advance).
If advancing during a bath, all water valves will turn off and the drain will
open until the “open drain” step is completed. The cycle will then continue to
the next bath or to the spin of the current bath if the programming includes
spin time.
If advancing during a chemical injection of a bath or after a chemical
injection of the bath but before the low water level is reached, the injector
will turn off and the hot and the cold water valves to the tub will turn on
until the low water level is reached or for 30 seconds, whichever comes first.
Then the drain will open and proceed to the next step after the “open drain”
step is completed.
If advancing before a chemical injection of the bath, the drain will open
immediately and the cycle will proceed to the next step when the “open drain”
step is completed.
If advancing during a spin, the tumbler will begin to decelerate immediately.
However the cycle may proceed to the next bath before the tumbler comes to a
complete stop. The cycle cannot be advanced further while the tumbler is
decelerating.
If a temperature PCB is installed in the I/O PCB and the temperature programmed
from 20 to 90 (Celsius), advancing will turn off the heater relay or steam
valve immediately, if either is on, and open the drain after a three second
delay. If the display shows a water temperature from 65 to 90 (may be
displayed by pressing the “DOWN” and “START” buttons together), the drain will
close again when the washer indicates empty and the hot and the cold water
valves to the tub will turn on until the low water level is reached. The cycle
will then continue to the next bath, or if programmed, to the spin of the
current bath.
To exit the Rapid Advance mode during the cycle, turn the key to Run. The
cycle will continue normally.