Dexter Laundry T-1450 EXPRESS (30-Cycle) User Manual
Page 13
13
required segments are edited. The previously stored parameters will appear as
each part of the segment data is reviewed.
6.
Push the green ENTER button.
The Cycle Time LED lights, (lower row of LED's), and the segment LED is
out. The tumble time for this segment will be shown on the display. If
no change is required, then continue to the next instruction. If this
value requires changing, then use the SCROLL UP/SCROLL DOWN buttons to
change the tumble time in 1 minute increments to the desired value, then
continue to the next instruction. Settings range is from 0 minutes to 30
minutes except for the Final Rinse/Extract segment where the setting
range is 1 minute to 30 minutes. REMINDER: If the tumble time is set to
zero, the segment will be skipped in the wash cycle.
7.
Push the green ENTER button. (The wash time has now been entered.)
The Water Temperature LED lights and the Cycle Time LED is out. The
water temperature for this segment is displayed. If no change is
required, then continue to the next instruction. If a change is
required, then use the SCROLL UP/SCROLL DOWN buttons to change the water
temperature. “HH” is all hot water, “CC” is all cold water, “CH” is an
even mix of hot and cold water and “EE” is a no water bath. Entering a
temperature value of 20-90C will result in a heated bath, if
temperature of fill water is less than programmed temperature. When the
desired water temperature is selected, continue to the next instruction.
8.
Push the green ENTER button. (The water temperature has now been
entered.)
The Water Level LED lights and the Water Temperature LED is out. The
water level for this segment is displayed. If no change is required,
then continue to the next instruction. If a change is required, then use
the SCROLL UP/SCROLL DOWN buttons to change the water level. ("HI" is a
high water level and "LO" is a low water level.) When the desired water
level is selected, continue to the next instruction.
When the No Water bath is selected, the water level has no effect.
Either water level can be selected.
9.
Push the green ENTER button. (The water level has now been entered.)
The Injection Source LED lights and the Water Level LED is out. The
injection source for this segment is displayed. If no change is
required, then continue to the next instruction. If a change is
required, then use the SCROLL UP/SCROLL DOWN buttons to change the
injection source. See the Injection Source Table for proper selection.
If zero is selected, then no injection source is active for this segment.
When the desired injection source is selected, continue to the next
instruction.
When the No Water bath is selected, injection signals are prohibited by
the electronic controller. The programmed injection source value is
ignored.
10. Push the green ENTER button. (The injection source has now been
entered.)
The Spin Time LED lights and the Injection Source LED is out. The spin
time for this segment is displayed. If no change is required, then
continue to the next instruction. If this value requires changing, then
use the SCROLL UP/SCROLL DOWN buttons to change the spin time in 1 minute
increments to the desired value, then continue to the next instruction.
Settings range is from 0 minutes to 10 minutes except for the Final
Rinse/Extract segment, where the setting range is 1 minute to 10 minutes.
REMINDER: If the spin time is set to zero, there will be no spin at the
end of the bath.