beautypg.com

Dexter Laundry T-1450 EXPRESS (30-Cycle) User Manual

Page 13

background image

13

required segments are edited. The previously stored parameters will appear as

each part of the segment data is reviewed.

6.

Push the green ENTER button.

The Cycle Time LED lights, (lower row of LED's), and the segment LED is

out. The tumble time for this segment will be shown on the display. If

no change is required, then continue to the next instruction. If this

value requires changing, then use the SCROLL UP/SCROLL DOWN buttons to

change the tumble time in 1 minute increments to the desired value, then

continue to the next instruction. Settings range is from 0 minutes to 30

minutes except for the Final Rinse/Extract segment where the setting

range is 1 minute to 30 minutes. REMINDER: If the tumble time is set to

zero, the segment will be skipped in the wash cycle.

7.

Push the green ENTER button. (The wash time has now been entered.)

The Water Temperature LED lights and the Cycle Time LED is out. The

water temperature for this segment is displayed. If no change is

required, then continue to the next instruction. If a change is

required, then use the SCROLL UP/SCROLL DOWN buttons to change the water

temperature. “HH” is all hot water, “CC” is all cold water, “CH” is an

even mix of hot and cold water and “EE” is a no water bath. Entering a

temperature value of 20-90C will result in a heated bath, if

temperature of fill water is less than programmed temperature. When the

desired water temperature is selected, continue to the next instruction.

8.

Push the green ENTER button. (The water temperature has now been

entered.)

The Water Level LED lights and the Water Temperature LED is out. The

water level for this segment is displayed. If no change is required,

then continue to the next instruction. If a change is required, then use

the SCROLL UP/SCROLL DOWN buttons to change the water level. ("HI" is a

high water level and "LO" is a low water level.) When the desired water

level is selected, continue to the next instruction.

When the No Water bath is selected, the water level has no effect.

Either water level can be selected.

9.

Push the green ENTER button. (The water level has now been entered.)

The Injection Source LED lights and the Water Level LED is out. The

injection source for this segment is displayed. If no change is

required, then continue to the next instruction. If a change is

required, then use the SCROLL UP/SCROLL DOWN buttons to change the

injection source. See the Injection Source Table for proper selection.

If zero is selected, then no injection source is active for this segment.

When the desired injection source is selected, continue to the next

instruction.

When the No Water bath is selected, injection signals are prohibited by

the electronic controller. The programmed injection source value is

ignored.

10. Push the green ENTER button. (The injection source has now been

entered.)

The Spin Time LED lights and the Injection Source LED is out. The spin

time for this segment is displayed. If no change is required, then

continue to the next instruction. If this value requires changing, then

use the SCROLL UP/SCROLL DOWN buttons to change the spin time in 1 minute

increments to the desired value, then continue to the next instruction.

Settings range is from 0 minutes to 10 minutes except for the Final

Rinse/Extract segment, where the setting range is 1 minute to 10 minutes.

REMINDER: If the spin time is set to zero, there will be no spin at the

end of the bath.