Dexter Laundry T-900 (Commercial) User Manual
Page 7
EMERGENCY STOP / SAFETY DOOR LOCK
This machine is equipped with a Safety Door Lock that locks the door closed from when the cycle is
started until the cycle is complete. The door lock prevents opening the door for up to 3 minutes if the
power is interrupted during the cycle.
The Emergency Stop button pauses the washer and allows the door to be opened during the cycle
after the Safety Door Lock releases. When the Emergency Stop button is pressed an alarm will
sound and the display will begin counting down from “3”. If the button is released before 3 seconds
elapse, the alarm will stop and the cycle will continue normally. If the Emergency Stop is held
down for 3 seconds, the display will count down to “0” and the washer will begin stopping
movement and water flow and begin draining water from inside the washer. Though the machine
may stop wash movement quickly, it may take up to 3 minutes for the door to unlock. During that
time the alarm will continue to sound. When the alarm stops, the door may be opened. The washer
may be restarted by closing and latching the door, and pressing the Start button. If the washer was
stopped more than once before the final extract, the cycle will be cancelled. If the washer was
stopped during final extract, the cycle will be ended. If the washer is stopped for more than 1 hour,
the cycle will be terminated.
SPECIFICATIONS
MODEL
T900/950 60LB WASHER
CAPACITY
CYLINDER SIZE
ELECTRICAL
DRIVE SYSTEM
WASH SPEED
INTERMEDIATE
EXTRACT
FINAL EXTRACT
MACHINE CONTROL
WATER INLET
DRAIN VALVE
60LBS/9 CUBIC FT. (27.2 kg/255 L)
30” DIA X 22” DEEP (76.2cm X 55.9cm)
208-240 VAC, 60 HZ, 1 OR 3 PHASE
SOFT START REVERSING INVERTER DRIVE
43 RPM
375 RPM (60 G’S)
484 RPM (100 G’S) / 573 RPM (140 G’S) / 685 (200 G’S)
PROGRAMMABLE COMPUTER WITH 6 STANDARD CYCLES.
4 SOLENOID OPERATED VALVES
FLOW RATE: 2 DUAL VALVES (9 GAL/MIN) EACH, 30-120
PSI,
2 SINGLE VALVES (12 GAL/MIN) EACH, 30-120 PSI
3” DIAMETER