3B Scientific Pressure Balance User Manual
Page 4
4
2
..... Description, technical data
Two precision-made glass syringes [
3
,
9
] of differing
volume are attached to an acrylic carrier plate
2
on top
of an anodised aluminium stand rod
4
. Each of the
plungers has a tray
1
for holding weights
bm
. The sy-
ringes are linked by a connecting hose
8
so that they
form a closed system
. An air inlet
7
allows air to be
drawn into the system
. A safety cord prevents the small
plunger flying out of the cylinder
. A rod
6
is included on
the base plate
5
upon which disc weights can be stacked
when not in use
.
Volume of syringes:
10 ml and 50 ml
Ratio of plunger
diameters:
10:3 (
∅ 26.9 mm : 14.7 mm)
Ratio of plunger masses
with tray:
10:3
Number of weights:
15
Mass of weights:
40 g each (approx
.)
Base plate dimensions:
140 mm x 100 mm
Total weight:
1
.2 kg
3
..... Operation
• Preparation: open the air inlet, pull out the large cyl-
inder to about the 20-30 ml mark then close the inlet
again
.
• Experiment procedure: first lay a weight onto the
small plunger
. Next lay weights one by one on top of
the large plunger
. When the fourth weight is laid on,
the plunger starts to descend
.
• Thus when the weight ratio is about 1 : 3.5 ± 0.5
weights, the system is in equilibrium
. This ratio is
confirmed by placing weights in the ratio of 2 : 7 (if
the plungers are very clean and weights precisely cen-
tered, the large plunger may start to descend)
. Equi-
librium is also apparent for a weight ratio of 3 : 10
.
• During the course of an experiment, air gradually
seeps out since syringes that were entirely airtight
would not move at all
. It may be necessary to let in
more air
.
4
..... Storage and cleaning
• For the equipment to function perfectly, it is essen-
tial that the plungers and cylinders are free of any
grease or dust
. Even fingerprints can affect the func-
tionality adversely
. The equipment can be cleaned
using methylated spirits (caution: flammable!)
. If the
safety cord is removed to facilitate cleaning, it can be
replaced by any suitable strong nylon cord (e
.g. but-
tonhole thread)
.
• The equipment should be stored in a dry, dust-free
location
.
3B Scientific GmbH • Rudorffweg 8 • 21031 Hamburg • Germany • www.3bscientific.com • Technical amendments are possible