Specifications:

Connections:

ZC-1, ZC-2, ZC-3, ZC-6, ZC-7, ZC-8 and ZC-9 Connectors: (2) RJ-45
ZC-4 Connectors: (2) RJ-45, (1) 6-pin Phoenix
ZC-BOB Connectors: (7) RJ-45
ZC-Fire Connectors (2) RJ-45, (2) 2-Pin Phoenix

Wiring:

Maximum Cable Length depends on number of Zone Controllers and wiring schematic.

Series Wiring:

Maximum Cable Length varies with number of Zone Controllers. For Example,Three Zone Controllers:
600 ft. Six Zone Controllers: 300 ft.

Parallel Wiring:

Using a ZC-BOB:Up to Six Zone Controllers: 1000 ft.
Cable: CAT5 or CAT5E with <28.6 Ohm/M (Ohm/1000 ft.) nominal DCR and rated VW-1 or higher.

Safety Agency Approvals:

UL 6500, IEC 60065, EN 55013, E60065

SHIPPING WEIGHT:

.7 lb.