beautypg.com

Installation – Zanussi ZBA23040SA User Manual

Page 18

background image

The technical information are situated in the rating plate

on the internal left side of the appliance and in the energy

label.

Installation

Caution! Read the "Safety Information" carefully for

your safety and correct operation of the appliance

before installing the appliance.

Positioning

Install this appliance at a location where the ambient tem-

perature corresponds to the climate class indicated on the

rating plate of the appliance:

Climate

class

Ambient temperature

SN

+10°C to + 32°C

N

+16°C to + 32°C

ST

+16°C to + 38°C

T

+16°C to + 43°C

Electrical connection

Before plugging in, ensure that the voltage and frequency

shown on the rating plate correspond to your domestic

power supply.

The appliance must be earthed. The power supply cable

plug is provided with a contact for this purpose. If the do-

mestic power supply socket is not earthed, connect the

appliance to a separate earth in compliance with current

regulations, consulting a qualified electrician.

The manufacturer declines all responsibility if the above

safety precautions are not observed.

This appliance complies with the E.E.C. Directives.

Door reversibility

The door of the appliance opens to the right. If you want to

open the door to the left, do these steps before you install

the appliance:

1

Loosen the upper pin

and remove the spacer.

2

Remove the upper pin

and the door.

3

Loosen the lower pin.

On the opposite side:

1

Install the lower pin.

2

Install the door.

3

Tighten the spacer and

tighten the upper pin.

Ventilation requirements

The airflow behind the ap-

pliance must be sufficient.

5 cm

min. 200cm

2

min.

200cm

2

Installing the appliance

Caution! Make sure that the mains cable can move

freely.

Do the following steps:

18