Bad height sensor configurations – Airbagit Air Management User Manual
Page 10

8
A I R B A G I T. C O M S U S P E N S I O N S
2 6 0 S . H I B B E R T, M E S A , A Z P H . 8 0 0 - 8 4 2 - 8 7 8 9
5. MOUNT THE HEIGHT SENSOR TO THE FRAME SO THAT THE TOP LINKAGE BALL JOINT IS
OVER THE PREVIOUSLY MARKED SPOT ON THE FRAME. THE ARM OF THE HEIGHT SENSOR
SHOULD BE SET IN THE MIDDLE OF ITS TRAVEL. DO NOT CONNECT THE LINKAGE YET.
6. INFLATE THE BAGS ALL THE WAY TO MAXIMUM LIFT.
7. CHECK TO MAKE SURE THE LINKAGE CAN BE CONNECTED BETWEEN THE LINK AND THE
HEIGHT SENSOR WITHOUT
OVERTRAVELING THE HEIGHT SENSOR OR WITHOUT AN EXCESSIVE AMOUNT OF ANGLE
BETWEEN THE HEIGHT SENSOR
ARM AND THE LINKAGE. DO NOT CONNECT THE LINKAGE YET. (SEE BELOW)
8. DEFLATE THE BAGS ALL THE WAY DOWN TO THE LOWEST POINT.
9. CHECK TO MAKE SURE THE LINKAGE CAN BE CONNECTED BETWEEN THE LINK AND THE
HEIGHT SENSOR WITHOUT OVERTRAVELING THE HEIGHT SENSOR AND WITHOUT AN
EXCESSIVE AMOUNT OF ANGLE BETWEEEN THE HEIGHT SENSOR ARM AND THE LINKAGE. TAKE
INTO CONSIDERATION THAT IF A VEHICLE IS LAID OUT ON THE FRAME RAILS AND THE FRONT IS
THEN LIFTED UP THE REAR SUSPENSION WILL TRAVEL HIGHER THAN WHEN IT IS LAID OUT
COMPLETELY AND COULD OVER TRAVEL THE SENSOR.
10. ONCE THE SENSORS HAVE BEEN THOROUGHLY CHECKED THE LINKAGE CAN BE CONNECTED.
11. THE WIRES CAN NOW BE RAN TO THE SMART-RIDE RELAY CONTROL BOX.
TIP: MARK THE BLUE PLUG TO IDENTIFY WHICH CORNER THE HEIGHT SENSOR IS MOUNTED TO.
OVER ROTATED
MOUNTED UPSIDE DOWN
BAD LINKAGE ANGLE
BAD LINKAGE
ANGLE
TOO LITTLE
SENSOR TRAVEL
BAD HEIGHT SENSOR CONFIGURATIONS