2 selection of the motor type – R&M Materials Handling VARIABLE SPEED CONTROLS CMXC 007 Service Manual User Manual
Page 9
![background image](/manuals/286978/9/background.png)
R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
9/9
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
Switch S3
Acceleration/deceleration
-1
-2
-3
-4
ramp time
0
1
0
1
8.0 sec
4.2
Selection of the motor type
The motor type is selected by switches S4-2, S4-3 and S4-4. There are several motor dependant parameters which
are set according to the selected motor (i.e. the operator selects a parameter set). The MF06-motors are selected
as follows:
S4
Motor type
Nominal frequency
Nominal power
-2
-3
-4
0
0
0
MF06MA200
100Hz (120Hz)
0.3kW (0.37kW)
1
0
0
MF06MA100
80Hz
0.65kW
0
1
0
MF06LA200
100Hz (120Hz)
0.45kW (0.55kW)
1
1
0
MF06LA100
80Hz
0.65kW
0
0
1
2*MF06MA200
100Hz (120Hz)
2*0.3kW (2*0.37kW)
1
0
1
MF06L-200
35 Hz
0.15kW