4V-600V ranges: 600V DC or 600V rms AC.

- Max. Input Voltage: 600V DC or rms AC

NOTE:

At the little voltage range, the meter will show
unsteady reading when test leads haven't reach
the circuit, it's normal because the meter is very
sensitivity. When test leads touch the circuit, you
can get the true reading.

3.2.2 AC Voltage

Range Resolution

Accuracy

4V 1mV

40V 10mV

400V 100mV

(0.8% of rdg + 3digits)

600V 1V

(1.5% of rdg + 5digits)

- Input Impedance: 10M

- Overload Protection: 400mV range: 250V DC or

rms AC, 4V-700V ranges: 600V DC or 600V
rms AC.

- Max. Input Voltage: 600V DC or rms AC
- Frequency Range: 40 to 400Hz
- Response: Average, calibrated in rms of sine

wave

NOTE:

At the little voltage range, the meter will show

- 14 -