Problem

Possible cause

Solution

Large quantities of food to be

frozen were put in at the same

time.

Insert smaller quantities of food

to be frozen at the same time.

The appliance does not

operate.

The appliance is switched off.

Switch on the appliance.

The mains plug is not connected

to the mains socket correctly.

Connect the mains plug to the

mains socket correctly.

The appliance has no power.

There is no voltage in the mains

socket.

Connect another electrical appli-

ance to the mains socket. Check

fuse. Contact a qualified electri-

cian.

The lamp does not work.

The lamp is defective.

Refer to "Replacing the lamp".

The door has been open to long.

Close the door.

Door interferes with venti-

lation grill.

The appliance is not levelled.

Refer to "Levelling".

Misaligned door.

The appliance is not levelled.

Refer to "Levelling".

As much as the advice does not lead to result, call the nearest brand-mark service.

Closing the door

1.

Clean the door gaskets.

2.

If necessary, adjust the door. Refer to "Installation".

3.

If necessary, replace the defective door gaskets. Contact the Service Center.

TECHNICAL DATA

Dimension

Height

1540 mm

Width

595 mm

Depth

658 mm

Rising Time

30 h

Voltage

230-240 V

Frequency

50 Hz

The technical information are situated in the rating plate on the internal left side of the

appliance and in the energy label.