Dc electrical characteristics (continued), Dc electrical characteristics – Rainbow Electronics MAX1848 User Manual
Page 3

MAX1848
White LED Step-Up Converter in SOT23
_______________________________________________________________________________________
3
DC ELECTRICAL CHARACTERISTICS (continued)
(V+ = 3V, V
OUT
= 11V, L = 33µH, C
OUT
= 1µF, C
COMP
= 0.15µF, R
SENSE
= 5
Ω, V
CTRL
= 1V, T
A
= 0
°C to +85°C, unless otherwise
noted. Typical values are at T
A
= +25
°C.)
DC ELECTRICAL CHARACTERISTICS
(V+ = 3V, V
OUT
= 11V, L = 33µH, C
OUT
= 1µF, C
COMP
= 0.15µF, R
SENSE
= 5
Ω, V
CTRL
= 1V, T
A
= -40
°C to +85°C, unless otherwise
noted. (Note 1)
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
N-CHANNEL SWITCH
LX On-Resistance
I
LX
= 100mA
1.4
2.2
Ω
T
A
= +25
°C
0.01
2
LX Leakage Current
V
OUT
= V
LX
= 13V
T
A
= +85
°C
0.05
µA
LX Current Limit
Duty cycle = 65%
300
500
750
mA
PARAMETER
CONDITIONS
MIN
MAX
UNITS
Supply Voltage
2.6
5.5
V
V+ rising, 40mV hysteresis typical
2.15
2.59
Undervoltage Lockout Threshold
V+ falling
2.10
2.56
V
Not switching, V
CTRL
= V
CS
= V+
0.4
Quiescent Current
Switching, V
CTRL
= V+, V
CS
= GND
2
mA
V+ rising, 1V hysteresis typical
12.25
14.00
Overvoltage Threshold
V+ falling
11.25
13.25
V
V
CTRL
> 0.25V
10
30
OUT Input Bias Current
V
OUT
= 13V
V
CTRL
= GND
1
µA
Output Voltage Range
V+ -
V
DIODE
12.25
V
ERROR AMPLIFIER
CTRL to CS Regulation
V
CTRL
= 2V, V+ = 2.6V to 5.5V
65
85
mV/V
CS Input Bias Current
V
CS
= V
CTRL
/13.33
1
µA
CTRL Input Resistance
450
1100
k
Ω
CTRL Dual Mode Threshold
Hysteresis = 25mV typical
100
240
mV
COMP Pin Resistance to Ground
Device in shutdown or overvoltage
7.5
50.0
k
Ω
COMP Output Voltage Swing
0.3
2.4
V
OSCILLATOR
Operating Frequency
0.9
1.6
MHz
Maximum Duty Cycle
V
CTRL
= V+, V
CS
= GND
85
97
%
N-CHANNEL SWITCH
LX On-Resistance
I
LX
= 100mA
2.2
Ω
LX Current Limit
Duty cycle = 65%
225
850
mA
Note 1: Limits are 100% production tested at T
A
= +25°C. Limits over the operating temperature range are guaranteed through cor-
relation using statistical quality control (SQC) methods.