DC ELECTRICAL CHARACTERISTICS (continued)

(V+ = 3V, V

OUT

= 11V, L = 33µH, C

OUT

= 1µF, C

COMP

= 0.15µF, R

SENSE

= 5

Ω, V

CTRL

= 1V, T

A

= 0

°C to +85°C, unless otherwise

noted. Typical values are at T

A

= +25

°C.)

DC ELECTRICAL CHARACTERISTICS

(V+ = 3V, V

OUT

= 11V, L = 33µH, C

OUT

= 1µF, C

COMP

= 0.15µF, R

SENSE

= 5

Ω, V

CTRL

= 1V, T

A

= -40

°C to +85°C, unless otherwise

noted. (Note 1)

PARAMETER

CONDITIONS

MIN

TYP

MAX

UNITS

N-CHANNEL SWITCH

LX On-Resistance

I

LX

= 100mA

1.4

2.2

T

A

= +25

°C

0.01

2

LX Leakage Current

V

OUT

= V

LX

= 13V

T

A

= +85

°C

0.05

µA

LX Current Limit

Duty cycle = 65%

300

500

750

mA

PARAMETER

CONDITIONS

MIN

MAX

UNITS

Supply Voltage

2.6

5.5

V

V+ rising, 40mV hysteresis typical

2.15

2.59

Undervoltage Lockout Threshold

V+ falling

2.10

2.56

V

Not switching, V

CTRL

= V

CS

= V+

0.4

Quiescent Current

Switching, V

CTRL

= V+, V

CS

= GND

2

mA

V+ rising, 1V hysteresis typical

12.25

14.00

Overvoltage Threshold

V+ falling

11.25

13.25

V

V

CTRL

> 0.25V

10

30

OUT Input Bias Current

V

OUT

= 13V

V

CTRL

= GND

1

µA

Output Voltage Range

V+ -

V

DIODE

12.25

V

ERROR AMPLIFIER

CTRL to CS Regulation

V

CTRL

= 2V, V+ = 2.6V to 5.5V

65

85

mV/V

CS Input Bias Current

V

CS

= V

CTRL

/13.33

1

µA

CTRL Input Resistance

450

1100

k

CTRL Dual Mode Threshold

Hysteresis = 25mV typical

100

240

mV

COMP Pin Resistance to Ground

Device in shutdown or overvoltage

7.5

50.0

k

COMP Output Voltage Swing

0.3

2.4

V

OSCILLATOR

Operating Frequency

0.9

1.6

MHz

Maximum Duty Cycle

V

CTRL

= V+, V

CS

= GND

85

97

%

N-CHANNEL SWITCH

LX On-Resistance

I

LX

= 100mA

2.2

LX Current Limit

Duty cycle = 65%

225

850

mA

Note 1: Limits are 100% production tested at T

A

= +25°C. Limits over the operating temperature range are guaranteed through cor-

relation using statistical quality control (SQC) methods.