beautypg.com

Typical operating characteristics – Rainbow Electronics MAX984 User Manual

Page 4

background image

MAX971–MAX974/MAX981–MAX984

Ultra-Low-Power, Open-Drain,
Single/Dual-Supply Comparators

4

_______________________________________________________________________________________

__________________________________________Typical Operating Characteristics

(V+ = 5V, V- = GND, T

A

= +25°C, unless otherwise noted.)

0

0

20

OUTPUT VOLTAGE LOW

vs. LOAD CURRENT

0.5

2.5

MAX971/4-TOC1

LOAD CURRENT (mA)

V

OL

(V)

12

1.5

1.0

4

8

16

2.0

V+ = 5V

V+ = 3V

1.155

0

5

15

25

REFERENCE OUTPUT VOLTAGE vs.

OUTPUT LOAD CURRENT

1.165

1.185

MAX971/4-TOC2

OUTPUT LOAD CURRENT (

µ

A)

REFERENCE OUTPUT VOLTAGE (V)

10

20

1.175

1.190

1.160

1.180

1.170

V+ = 5V

OR

V+ = 3V

30

SINK

SOURCE

1.22

1.14

-60

-20

60

140

MAX971/MAX973/MAX974

REFERENCE VOLTAGE vs. TEMPERATURE

1.16

1.20

MAX971/4-TOC3

TEMPERATURE (

°

C)

REFERENCE VOLTAGE (V)

20

100

1.18

1.21

1.15

1.19

1.17

-40

0

80

40

120

MILITARY TEMP. RANGE

EXTENDED TEMP. RANGE

COMMERCIAL

TEMP. RANGE

ELECTRICAL CHARACTERISTICS: 3V OPERATION (continued)

(V+ = 5V, V- = GND = 0V, T

A

= T

MIN

to T

MAX

, unless otherwise noted. Typical values are at T

A

= +25°C.)

CONDITIONS

Output Low Voltage

GND + 0.4

V

V- + 0.4

MAX9_1/MAX9_4, I

OUT

= 0.8mA for C/E temp. ranges,

I

OUT

= 0.6mA for M temp. range

MAX9_2/MAX9_3, I

OUT

= 0.8mA for C/E temp. ranges,

I

OUT

= 0.6mA for M temp. range

µs

4

T

A

= +25°C, 100pF load,

1M

pull-up to V+

Overdrive = 100mV

Response Time
(high-to-low transition)

µV

RMS

20

100Hz to 100kHz

Voltage Noise

V

12

REF - 0.05

REF

Overdrive = 10mV

MAX9_1/MAX982/MAX9_3

Output Leakage Current

nA

100

Hysteresis Input Voltage Range

V

OUT

= 11V

UNITS

MIN TYP MAX

PARAMETER

1.158

1.206

1.170

1.182

1.194

15

25

Reference Voltage

V

1.147

1.217

Source Current

µA

4

6

Voltage Noise

µV

RMS

100

100Hz to 100kHz

C temp. range

E temp. range

M temp. range

T

A

= +25°C

C/E temp. ranges

M temp. range

µs

300

T

A

= +25°C, 100pF load, 1M

pull-up to V+

Response Time
(low-to-high transition) (Note 2)

Note 1:

MAX974/MAX984 comparators work below 2.5V; see

Low-Voltage

Operation section for more details.

Note 2:

Low-to-high response time is the result of the 1M

pull-up and the 100pF capacitive load, based on three time constants.

A faster response time is achieved with a smaller RC.

4

8

15

Sink Current

µA

2

T

A

= +25°C

C/E temp. ranges

M temp. range

REFERENCE