Typical operating characteristics, Timing characteristics – Rainbow Electronics MAX1621 User Manual
Page 5

MAX1620/MAX1621
Digitally Adjustable LCD Bias Supplies
_______________________________________________________________________________________
5
TIMING CHARACTERISTICS
(V
DD
= 3.3V, V
BATT
= 10V,
T
A
= -40°C to +85°C
. Typical values are at T
A
= +25°C, unless otherwise noted. Limits over this
temperature range are guaranteed by design.)
CONDITIONS
4
Stop Condition SCL_ to SDA_
Setup Time
µs
t
SU:STO
µs
4
t
HD:STA
Start Condition SDA_ to SCL_
Hold Time
µs
4.7
t
SU:STA
Start Condition SCL_ to SDA_
Setup Time
µs
4
t
HIGH
SCL High Time
µs
4.7
t
LOW
SCL Low Time
ns
300
t
F
SCL/SDA Fall Time
µs
1
t
1
Pulse Width High (UP, DN)
µs
1
t
R
SCL/SDA Rise Time
ns
0
t
HD:DAT
SCL_ to SDA_ Data-Hold Time
ns
500
t
SU
:
DAT
SDA_ to SCL_ Data-Setup Time
µs
1
t
2
Pulse Width Low (UP, DN)
µs
1
t
3
Pulse Separation (UP, DN)
µs
1
t
4
Counter Reset Time
UNITS
MIN
TYP
MAX
SYMBOL
PARAMETER
Note 1:
The setting in the DAC is guaranteed to remain valid as long as V
DD
is greater than the UVLO threshold.
Note 2:
BATT Operating Range is guaranteed by the Microsecond-Volt Time Constant specification.
Note 3:
Current sourced from a pin is denoted as positive current. Current sunk into a pin is denoted as negative current.
Note 4:
Guaranteed by design.
__________________________________________Typical Operating Characteristics
(V
DD
= 5V, V
BATT
= 10V, L1 = 100µH, T
A
= +25°C, unless otherwise noted.)
0.70
0.75
0.80
0.85
0.90
0.95
1.00
0
10
20
30
40
50
60
70
EFFICIENCY vs. OUTPUT CURRENT
MAX1620/21-01
OUTPUT CURRENT (mA)
EFFICIENCY (%)
+25V
+15V
0.70
0.75
0.80
0.85
0.90
0.95
1.00
0
10
20
30
40
50
60
70
EFFICIENCY vs. OUTPUT CURRENT
MAX1620/21-02
OUTPUT CURRENT (mA)
EFFICIENCY (%)
-25V
-15V
0.70
0.75
0.80
0.85
0.90
0.95
1.00
12
14
16
18
20
22
24
26
EFFICIENCY vs. OUTPUT VOLTAGE
MAX1620/21-03
OUTPUT VOLTAGE (V)
EFFICIENCY (%)
+10mA
+20mA
1
SCL Falling Time to SDA Valid
Master Clocking in Data
µs
t
DV
MAX1620
(Figure 1)
MAX1621
(Figures 2 and 3)