Ac electrical characteristics (v – Rainbow Electronics DS1602 User Manual
Page 8

DS1602
8 of 8
AC ELECTRICAL CHARACTERISTICS
(V
CC
= +5V ±10%; -40°C to 85°C)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Data to CLK Setup
t
DC
50
ns
7
CLK to Data Hold
t
CDH
60
ns
7
CLK to Data Delay
t
CDD
200
ns
7, 8, 9
CLK Low Time
t
CL
250
ns
7
CLK High Time
t
CH
250
ns
7
CLK Frequency
f
CLK
DC
2.0
MHz
7
CLK Rise and Fall
t
F,
t
R
500
ns
RST
to CLK Setup
t
CC
100
ns
7
CLK to
RST
Hold
t
CCH
60
ns
7
RST
Inactive Time
t
CWH
1
µs
7
RST
Low to I/O High-Z
t
RDZ
70
ns
7
CLK High to I/O High- Z
t
CDZ
20
ns
7
NOTES:
1) All voltages are referenced to ground.
2) Logic 1 voltages are specified at a source current of 1mA.
3) Logic 0 voltages are specified at a sink current of 4mA.
4) I
CC
is specified with the DQ pin open.
5) I
CC1
is specified with V
CC
at 5.0V and
RST
= GND.
6) I
BAT
is specified with V
CC
< V
BAT
and V
BAT
within DC recommended operating conditions.
7) Measured at V
IH
= 2.0V or V
IL
= 0.8V.
8) Measured at V
OH
= 2.4V or V
OL
= 0.4V.
9) Load capacitance = 50pF.
10) Specified as the load capacitance for which the crystal frequency is guaranteed (see crystal
manufacturer’s data sheet).
11) Leakage current is the amount of current consumed from the battery when V
CC
is not present and the
oscillator is turned off.
12) Using a crystal on X1 and X2.