Table 1. valid protocols – Rainbow Electronics DS1602 User Manual
Page 5

DS1602
5 of 8
Table 1. VALID PROTOCOLS
PROTOCOL
ACTION
ACC
AVC
OSC2
OSC1 OSC0 CCC CVC RD
FUNCTION
Read
Continuous
Counter
1
0
X
X
X
X
X
1
Output continuous
counter on the 32 clocks
following protocol.
Oscillator trim register
is not updated. Counters
are not reset.
Write
Continuous
Counter
1
0
X
X
X
X
X
0
Input data to continuous
counter on the 32 clocks
following protocol.
Oscillator trim register
is not updated. Counters
are not reset.
Read V
CC
Active
Counter
0
1
X
X
X
X
X
1
Output V
CC
active
counter on the 32 clocks
following protocol,
oscillator trim register
is not updated. Counters
are not reset.
Write V
CC
Active
Counter
0
1
X
X
X
X
X
0
Input data to continuous
counter on the 32 clocks
following protocol.
Oscillator trim register
is not updated. Counters
are not reset.
Clear
Continuous
Counter
0
0
X
X
X
1
X
X
Resets the continuous
counter to all zeros at
the end of protocol.
Oscillator trim register
is not updated.
Clear V
CC
Active
Counter
0
0
X
X
X
X
1
X
Resets the V
CC
active
counter to all zeros at
the end of protocol.
Oscillator trim register
is not updated.
Set Oscillator
Trim Bits
1
1
A
B
C
X
X
0
Sets the oscillator trim
register to a value of
ABC. Counters are
unaffected.
X = Don’t Care