Phantom clock ac electrical characteristics, Power-down/power-up timing – Rainbow Electronics DS1244Y User Manual
Page 10

DS1244/DS1244P
10 of 19
PHANTOM CLOCK AC ELECTRICAL CHARACTERISTICS
Over the operating range (5V)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Read Cycle Time
t
RC
65
ns
CE
Access Time
t
CO
55
ns
OE
Access Time
t
OE
55
ns
CE
to Output Low-Z
t
COE
5
ns
OE
to Output Low-Z
t
OEE
5
ns
CE
to Output High-Z
t
OD
25
ns
5
OE
to Output High-Z
t
ODO
25
ns
5
Read Recovery
t
RR
10
ns
Write Cycle Time
t
WC
65
ns
Write Pulse Width
t
WP
55
ns
3
Write Recovery
t
WR
10
ns
10
Data Setup Time
t
DS
30
ns
4
Data Hold Time
t
DH
0
ns
4
CE
Pulse Width
t
CW
60
ns
RESET
Pulse Width
t
RST
65
ns
POWER-DOWN/POWER-UP TIMING
Over the operating range (5V)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
CE
at V
IH
before Power-Down
t
PD
0
ms
V
CC
Slew from V
PF(max)
to
V
PF(min)
(
CE
at V
PF
)
t
F
300
ms
V
CC
Slew from V
PF(min)
to V
SO
t
FB
10
ms
V
CC
Slew from V
PF(max)
to
V
PF(min)
(
CE
at V
PF
)
t
R
0
ms
CE
at V
IH
after Power-Up
t
REC
1.5
2.5
ms
(T
A
= +25°C)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Expected Data Retention Time
t
DR
10
years
9
Warning: Under no circumstances are negative undershoots of any amplitude allowed when device is in
battery-backup mode.