In dual pushbutton mode, each direction is controlled by the up contact (UC) and down contact (DC)
inputs, respectively. No wait states are required to change wiper direction in dual pushbutton mode. In
dual pushbutton mode, as the wiper position reaches the end of the potentiometer, the direction of wiper
movement will not change. Wiper position will remain at the potentiometers’ end until an opposite
direction input is given.

All contact closure control inputs, UC, DC, and D, are internally pulled-up by a 100 k

Ω=resistance. The

UC and DC inputs are internally debounced and require no external components for input signal
conditioning.

DS1869 SINGLE PUSHBUTTON CONFIGURATION
(TYPICAL EXAMPLE)
Figure 1

DS1869 DUAL PUSHBUTTON CONFIGURATION
(TYPICAL EXAMPLE)
Figure 2A