Rainbow Electronics DS1620 User Manual
Page 8

DS1620
8 of 13
DS1620 COMMAND SET Table 3
INSTRUCTION
DESCRIPTION
PROTOCOL
3-WIRE BUS
DATA AFTER
ISSUING
PROTOCOL
NOTES
TEMPERATURE CONVERSION COMMANDS
Read Temperature
Reads last converted temperature
value from temperature register.
AAh
Read Counter
Reads value of count remaining
from counter.
A0h
Read Slope
Reads value of the slope
accumulator.
A9h
Start Convert T
Initiates temperature conversion.
EEh
Idle
1
Stop Convert T
Halts temperature conversion.
22h
Idle
1
THERMOSTAT COMMANDS
Write TH
Writes high temperature limit value
into TH register.
01h
2
Write TL
Writes low temperature limit value
into TL register.
02h
2
Read TH
Reads stored value of high
temperature limit from TH register.
A1h
2
Read TL
Reads stored value of low
temperature limit from TL register.
A2h
2
Write Config
Writes configuration data to
configuration register.
0Ch
2
Read Config
Reads configuration data from
configuration register.
ACh
2
NOTES:
1. In continuous conversion mode, a Stop Convert T command will halt continuous conversion. To
restart, the Start Convert T command must be issued. In one–shot mode, a Start Convert T command
must be issued for every temperature reading desired.
2. Writing to the E
2
typically requires 10 ms at room temperature. After issuing a write command no
further writes should be requested for at least 10 ms.