DS1620

8 of 13

DS1620 COMMAND SET Table 3

INSTRUCTION

DESCRIPTION

PROTOCOL

3-WIRE BUS

DATA AFTER

ISSUING

PROTOCOL

NOTES

TEMPERATURE CONVERSION COMMANDS

Read Temperature

Reads last converted temperature
value from temperature register.

AAh

Read Counter

Reads value of count remaining
from counter.

A0h

Read Slope

Reads value of the slope
accumulator.

A9h

Start Convert T

Initiates temperature conversion.

EEh

Idle

1

Stop Convert T

Halts temperature conversion.

22h

Idle

1

THERMOSTAT COMMANDS

Write TH

Writes high temperature limit value
into TH register.

01h

2

Write TL

Writes low temperature limit value
into TL register.

02h

2

Read TH

Reads stored value of high
temperature limit from TH register.

A1h

2

Read TL

Reads stored value of low
temperature limit from TL register.

A2h

2

Write Config

Writes configuration data to
configuration register.

0Ch

2

Read Config

Reads configuration data from
configuration register.

ACh

2

NOTES:

1. In continuous conversion mode, a Stop Convert T command will halt continuous conversion. To

restart, the Start Convert T command must be issued. In one–shot mode, a Start Convert T command
must be issued for every temperature reading desired.

2. Writing to the E

2

typically requires 10 ms at room temperature. After issuing a write command no

further writes should be requested for at least 10 ms.