Function select table, Truth table for receiver zero, Truth table for receiver one – Rainbow Electronics DS92LV222A User Manual
Page 6: Truth table for current drive, Applications information

Function Select Table
MODE SELECTED
DE0
DE1
RSEL
Receiver Zero ON, Driver Zero ON, Driver One OFF
H
L
L
Receiver Zero ON, Driver Zero OFF, Driver One ON
L
H
L
Receiver One ON, Driver Zero ON, Driver One OFF
H
L
H
Receiver One ON, Driver Zero OFF, Driver One ON
L
H
H
Receiver Zero ON, Driver Zero ON, Driver One ON
H
H
L
Receiver One ON, Driver Zero ON, Driver One ON
H
H
H
Driver Zero and Driver One TRI-STATE
L
L
X
Truth Table for Receiver Zero
INPUTS
OUTPUTS
DE0
RSEL
(RI0+)–(RI0−)
DO+
DO−
H
L
L
L
H
H
L
H
H
L
H
L
100 mV
>
&
>
−100 mV
X
X
L
X
X
Z
Z
X = High or low logic state
Z = High impedance state
L = Low state
Truth Table for Receiver One
INPUTS
OUTPUTS
DE1
RSEL
(RI1+)–(RI1−)
DO+
DO−
H
H
L
L
H
H
H
H
H
L
H
H
100 mV
>
&
>
−100 mV
X
X
L
X
X
Z
Z
X = High or low logic state
Z = High impedance state
L = Low state
Truth Table for Current Drive
Driver
Current Drive
ISEL0
ISEL1
Driver 0
3.5 mA
H
X
Driver 0
8.5 mA
L
X
Driver 1
3.5 mA
X
H
Driver 1
8.5 mA
X
L
Applications Information
There are few common practices which should be employed
when designing PCB for Bus LVDS signaling. Recom-
mended practices are:
•
Use at least 4 PCB board layer (Bus LVDS signals,
ground, power and TTL signals).
•
Keep drivers and receivers as close to the (Bus LVDS
port side) connector as possible.
•
Bypass each Bus LVDS device and also use distributed
bulk capacitance. Surface mount capacitors placed close
to power and ground pins work best. Two or three multi-
layer ceramic (MLC) surface mount capacitors (0.1µ and
0.01 µF in parallel should be used between each V
CC
and
ground. The capacitors should be as close as possible to
the V
CC
pin.
•
Use controlled impedance traces which match the differ-
ential impedance of your transmission medium (i.e.,
Cable) and termination resistor.
•
Use the termination resistor which best matches the dif-
ferential impedance of your transmission line.
•
Leave unused Bus LVDS receiver inputs open (floating).
•
Isolate TTL signals from Bus LVDS signals.
MEDIA (CABLE, CONNECTOR OR BACKPLANE)
SELECTION:
•
Use controlled impedance media. The cables and con-
nectors should have a matched differential impedance.
•
Balanced cables (e.g., twisted pair) are usually better
than unbalanced cables (ribbon cable, simple coax) for
noise reduction and signal quality.
•
•
There are different types of failsafe situations to consider,
these are Open Input, Terminated Input, and other spe-
cial cases. The first, Open input failsafe occurs when only
one receiver is being used (R0 for example). The unused
receiver (R1) inputs should be left open for noise minimi-
zation. The second case is for terminated inputs. This oc-
curs when the inputs have a low impedance (typically 100
Ohm) termination (R
T
) across them, and the cable is un-
plugged. For this case, and if the output state needs to
maintain a known state, two external bias resistors may
be used to provide a strong common mode bias point.
For this a 10K Ohm pull up and pull down resistor may be
used to set the output high. Note that R
1
and R
2
should
be much larger ( 2 orders of magnitude) compared to R
T
to minimize loading effects to the Bus LVDS driver when
it is active.
www.national.com