MAX6646/MAX6647/MAX6649

+145°C Precision SMBus-Compatible Remote/

Local Sensors with Overtemperature Alarms

______________________________________________________________________________________

11

Slave Addresses

The MAX6646/MAX6647/MAX6649 have fixed slave
addresses (see Table 9). All devices also respond to the
SMBus alert response slave address (see the Alert
Response Address
section).

POR and UVLO

To prevent ambiguous power-supply conditions from
corrupting the data in memory and causing erratic
behavior, a POR voltage detector monitors V

CC

and

clears the memory if V

CC

falls below 2.0V (typ). When

power is first applied and V

CC

rises above 2.0V (typ),

the logic blocks begin operating, although reads and
writes at V

CC

levels below 3V are not recommended. A

second V

CC

comparator, the ADC UVLO comparator,

prevents the ADC from converting until there is sufficient
headroom (V

CC

= 2.7V typ).

Power-Up Defaults

Power-up defaults include:

• Interrupt latch is cleared.

• ADC begins autoconverting at a 4Hz rate.

• Command byte is set to 00h to facilitate quick local

temperature receive byte queries.

• Local (internal) T

HIGH

limit is set to +85°C.

• Local (internal) T

LOW

limit is set to 0°C.

• Remote (external) T

HIGH

limit is set to +85°C

(MAX6649)/+95°C (MAX6646/MAX6647)

• OVERT (internal) limit is set to +85°C

• OVERT (external) limit is set to +85°C (MAX6649)/

+125°C (MAX6646/MAX6647)

DATA

CONVERSION

RATE (Hz)

00h

0.0625

01h

0.125

02h

0.25

03h

0.5

04h

1

05h

2

06h

4

07h

4

08h-FFh

Reserved

Table 8. Conversion-Rate Control Byte
(04h)

BIT

NAME

POR

STATE

FUNCTION

7 (MSB)

BUSY

0

A/D is busy converting when 1.

6

LHIGH

0

Local (internal) high-temperature alarm has tripped when 1; cleared by POR or readout of the
status byte if the fault condition no longer exists.

5

LLOW

0

Local (internal) low-temperature alarm has tripped when 1; cleared by POR or readout of the
status byte if the fault condition no longer exists.

4

RHIGH

0

Remote (external) high-temperature alarm has tripped when 1; cleared by POR or readout of the
status byte if the fault condition no longer exists.

3

RLOW

0

Remote (external) low-temperature alarm has tripped when 1; cleared by POR or readout of the
status byte if the fault condition no longer exists.

2

FAULT

0

A 1 indicates DXN and DXP are either shorted or open; cleared by POR or readout of the status
byte if the fault condition no longer exists.

1

EOT

0

A 1 indicates the remote (external) junction temperature exceeds the external

OVERT threshold.

0

IOT

0

A 1 indicates the local (internal) junction temperature exceeds the internal

OVERT threshold.

Table 7. Status Register Bit Assignments (02h)

PART

SLAVE ADDRESS

MAX6646

1001 101

MAX6647

1001 110

MAX6649

1001 100

Table 9. Slave Addresses