General Description

The MAX6646/MAX6647/MAX6649 are precise, two-
channel digital temperature sensors. The devices accu-
rately measure the temperature of their own die and a
remote PN junction, and report the temperature in digital
form using a 2-wire serial interface. The remote PN junc-
tion is typically the emitter-base junction of a common-
collector PNP on a CPU, FPGA, or ASIC.

The 2-wire serial interface accepts standard system man-
agement bus (SMBus) write byte, read byte, send byte,
and receive byte commands to read the temperature
data and to program the alarm thresholds. To enhance
system reliability, the MAX6646/MAX6647/MAX6649
include an SMBus timeout. A fault queue prevents the
ALERT and OVERT outputs from setting until a fault has
been detected one, two, or three consecutive times
(programmable).

The MAX6646/MAX6647/MAX6649 provide two system
alarms: ALERT and OVERT. ALERT asserts when any of
four temperature conditions are violated: local overtem-
perature, remote overtemperature, local undertempera-
ture, or remote undertemperature. OVERT asserts when
the temperature rises above the value in either of the two
OVERT limit registers. The OVERT output can be used to
activate a cooling fan, or to trigger a system shutdown.

Measurements can be done autonomously, at the pro-
grammed conversion rate, or in a single-shot mode. The
adjustable conversion rate allows optimizing supply cur-
rent and temperature update rate to match system needs.

Remote accuracy is ±1°C maximum error between +60°C
and +145°C with no calibration needed. The
MAX6646/MAX6647/MAX6649 operate from -55°C to
+125°C, and measure temperatures between 0°C and
+145°C. The MAX6646/MAX6647/MAX6649 are available
in an 8-pin µMAX package.

Applications

Graphics Processors

Desktop Computers

Notebook Computers

Servers

Thin Clients

Workstations

Test and Measurement

Multichip Modules

Features

Dual Channel: Measures Remote and Local

Temperature

0.125°C Resolution
High Accuracy ±1°C (max) from +60°C to +145°C

(Remote), and ±2°C (max) from +60°C to +100°C
(Local)

Measures High-Ideality Thermal Diodes Up to

+170°C (Apparent)
+145°C (Real)

Two Alarm Outputs: ALERT and OVERT
Programmable Under/Overtemperature Alarm

Temperature Thresholds

Programmable Conversion Rate
SMBus-Compatible Interface
SMBus Timeout

MAX6646/MAX6647/MAX6649

+145°C Precision SMBus-Compatible Remote/

Local Sensors with Overtemperature Alarms

________________________________________________________________ Maxim Integrated Products

1

Ordering Information

V

CC

DXP

DXN

10k

Ω EACH

CLOCK

TO FAN DRIVER OR
SYSTEM SHUTDOWN

3.3V

DATA

INTERRUPT TO

µP

200

0.1

µF

SDA

SCLK

ALERT

GND

2200pF

µP

MAX6646
MAX6647
MAX6649

OVERT

Typical Operating Circuit

19-2540; Rev 1; 7/03

For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.

PART

TEMP RANGE

PIN-
PACKAGE

MEASURED

TEMP RANGE

MAX6646MUA -55°C to +125°C 8 µMAX

0°C to +145°C

MAX6647MUA -55°C to +125°C 8 µMAX

0°C to +145°C

MAX6649MUA -55°C to +125°C 8 µMAX

0°C to +145°C

Selector Guide, Pin Configurations, and Functional Diagram