MAX16054

Human Body Model

Figure 2a shows the Human Body Model, and Figure
2b shows the current waveform it generates when dis-
charged into a low impedance. This model consists of a
100pF capacitor charged to the ESD voltage of interest,
which is then discharged into the test device through a
1.5kΩ resistor.

IEC 61000-4-2

The IEC 61000-4-2 standard covers ESD testing and
performance of finished equipment; it does not specifi-
cally refer to integrated circuits. The MAX16054 helps in
the design of equipment that meets IEC 61000-4-2, with-
out the need for additional ESD-protection components.

The major difference between tests done using the
Human Body Model and IEC 61000-4-2 is higher peak
current in IEC 61000-4-2, because series resistance is

lower in the IEC 61000-4-2 model. Hence, the ESD with-
stand voltage measured to IEC 61000-4-2 is generally
lower than that measured using the Human Body Model.
Figure 3a shows the IEC 61000-4-2 model, and Figure
3b shows the current waveform for the IEC 61000-4-2
ESD Contact-Discharge test.

The Air-Gap test involves approaching the device with a
charged probe. The Contact-Discharge method connects
the probe to the device before the probe is energized.

Machine Model

The Machine Model for ESD tests all pins using a
200pF storage capacitor and zero discharge resis-
tance. Its objective is to emulate the stress caused by
contact that occurs with handling and assembly during
manufacturing.

On/Off Controller with Debounce and
±15kV ESD Protection

6

_______________________________________________________________________________________

CHARGE-CURRENT

LIMIT RESISTOR

DISCHARGE

RESISTANCE

STORAGE
CAPACITOR

Cs

100pF

R

C

1M

Ω

R

D

1500

Ω

HIGH-

VOLTAGE

DC

SOURCE

DEVICE

UNDER

TEST

Figure 2a. Human Body ESD Test Model

CHARGE-CURRENT

LIMIT RESISTOR

DISCHARGE

RESISTANCE

STORAGE
CAPACITOR

Cs

150pF

R

C

50M

Ω to 100MΩ

R

D

330

Ω

HIGH-

VOLTAGE

DC

SOURCE

DEVICE

UNDER

TEST

Figure 2b. Human Body Current Waveform

I

P

100%

90%

36.8%

t

RL

TIME

t

DL

CURRENT WAVEFORM

PEAK-TO-PEAK RINGING
(NOT DRAWN TO SCALE)

Ir

10%

0

0

AMPERES

Figure 3a. IEC 61000-4-2 ESD Test Model

tR = 0.7ns TO 1ns

30ns

60ns

t

100%

90%

10%

I

PEAK

I

Figure 3b. IEC 61000-4-2 ESD Generator Current Waveform