beautypg.com

Typical operating characteristics (continued), Pin description – Rainbow Electronics MAX14523C User Manual

Page 7

background image

MAX14523A/MAX14523AL/MAX14523B/MAX14523C

250mA to 1.5A, Adjustable

Current-Limit Switches

_______________________________________________________________________________________

7

Typical Operating Characteristics (continued)

(V

IN

= +3.3V, C

IN

= 1µF, C

OUT

= 1µF, R

SETI

= 94.2k

Ω, T

A

= +25°C, unless otherwise noted.)

CURRENT LIMIT RESPONSE

MAX14523A toc13

2

μs/div

V

OUT

2V/div

I

OUT

10A/div

SUDDEN SHORT
APPLIED AT OUTPUT

CURRENT LIMIT RESPONSE

MAX14523A toc14

20ms/div

V

OUT

2V/div

I

OUT

1A/div

R

LOAD

= 16.5

Ω TO SUDDEN SHORT

APPLIED AT OUTPUT

FLAG RESPONSE (OVERLOAD CONDITION)

MAX14523A toc15

20ms/div

V

FLAG

2V/div

I

OUT

1A/div

R

LOAD

= 16.5

Ω TO SUDDEN SHORT

APPLIED AT OUTPUT

Pin Description

PIN

MAX14523AL

MAX14523A
MAX14523B
MAX14523C

NAME

FUNCTION

1, 6

1, 6

N.C.

No Connection. Not internally connected. Connect N.C. to GND or leave unconnected.

2 2

FLAG

Open-Drain, Overload Indicator Output.

FLAG goes low when the overload fault

duration exceeds the blanking time, reverse current is detected, thermal shutdown
mode is active, or SETI is connected to ground.

3 3

SETI

Overload-Current Limit Adjust. Connect a resistor from SETI to GND to program the
overcurrent limit. If SETI is connected to GND the switch turns off and

FLAG is

asserted. If SETI is unconnected the current limit is at 0mA. Do not connect any
capacitance larger than 20pF to SETI.

4

4

OUT

Switch Output. Bypass OUT with a 1μF capacitor to GND.

5 5

IN

Power Input. Bypass IN with a 1μF ceramic capacitor to GND. Use higher
capacitance if necessary to prevent large load transients from pulling down the
supply voltage.

7

ON

Active-Low, Switch-ON Input. Drive

ON low to turn on the switch.

7

ON

Active-High, Switch-ON Input. Drive ON high to turn on the switch.

8 8

GND

Ground

— —

EP

Exposed Pad. Internally connected to GND. For enhanced thermal dissipation,
connect EP to a large copper ground plane. Do not use EP as the sole ground