MAX6642

(0001 100). Following such a broadcast, any slave
device that generated an interrupt attempts to identify
itself by putting its own address on the bus.

The alert response can activate several different slave
devices simultaneously, similar to the I

2

C General Call.

If more than one slave attempts to respond, bus arbitra-
tion rules apply, and the device with the lower address
code wins. The losing device does not generate an
acknowledge and continues to hold the ALERT line low
until cleared. (The conditions for clearing an ALERT
vary depending on the type of slave device.)
Successful completion of the alert response protocol
clears the interrupt latch. If the condition still exists, the
device reasserts the ALERT interrupt at the end of the
next conversion.

Command Byte Functions

The 8-bit command byte register (Table 3) is the master
index that points to the various other registers within the
MAX6642. The register’s POR state is 0000 0000, so a
Receive Byte transmission (a protocol that lacks the

±1°C, SMBus-Compatible Remote/Local
Temperature Sensor with Overtemperature Alarm

8

_______________________________________________________________________________________

A D D R ESS

PO R ST A T E

F U N C T IO N

00h

00h ( 0000 0000)

Read l ocal tem p er atur e

01h

00h ( 0000 0000)

Read r em ote tem p er atur e

02h

N /A

Read status b yte

03h

10h ( 0001 0000)

Read confi g ur ati on b yte

05h

46h ( 0100 0110) + 70

° C Read

l ocal hi g h l i m i t

07h

78h ( 0111 1000) + 120

° C Read

r em ote hi g h l i m i t

09h

N /A

W r i te confi g ur ati on b yte

0Bh

N /A

W r i te l ocal hi g h l i m i t

0D h

N /A

W r i te r em ote hi g h l i m i t

0Fh

N /A

S i ng l e shot

10h

0000 0000

Read r em ote extend ed
tem p er atur e

11h

0000 0000

Read i nter nal extend ed
tem p er atur e

FE h

4D h ( 0100 1101)

Read m anufactur er ID

Table 3. Command-Byte Assignments

BIT

NAME

POR STATE

FUNCTION

7 (MSB)

MASK1

0

A 1 masks off (disables) the

ALERT interrupts.

6

STOP/RUN

0

A 1 puts the MAX6642 into standby mode.

5

External only

0

A 1 disables local temperature measurements so that only
remote temperature is measured. The measurement rate
becomes 8Hz.

4

Fault

queue

1

0:

ALERT is set by a single fault. 1: Two consecutive faults

are required to set

ALERT.

3 to 0

0000

Reserved.

Table 4. Configuration-Byte Bit Assignments

BIT

NAME

POR STATE

FUNCTION

7 (MSB)

BUSY

0

A 1 indicates the MAX6642 is busy converting.

6

LHIGH

0

A 1 indicates an internal high-temperature fault. Clear
LHIGH with a POR or by reading the status byte.

5

0

Reserved.

4

RHIGH

0

A 1 indicates an external high-temperature fault. Clear
RHIGH with a POR or by reading the status byte.

3

0

Reserved.

2

OPEN

0

A 1 indicates a diode open condition. Clear OPEN with a
POR or by reading the status byte when the condition no
longer exists.

1 to 0

0

Reserved.

Table 5. Status-Byte Bit Assignments