beautypg.com

Detailed description, Pin description (continued) – Rainbow Electronics MAX14998 User Manual

Page 7

background image

Two-Lane and Four-Lane DisplayPort Passive

Switches with Separate AUX/HPD Control

MAX4998/MAX14998

_______________________________________________________________________________________ 7

Detailed Description

The MAX4998/MAX14998 high-speed passive switches
route one DisplayPort source between two possible
destinations or vice versa. The MAX4998 is used to
switch two-lanes plus AUX/HPD DisplayPort, and the
MAX14998 is used to switch four-lanes plus AUX/HPD
DisplayPort.
The MAX4998/MAX14998 feature two digital control
inputs (SEL1, SEL2) to switch signal paths.

Digital Control Inputs (SEL1, SEL2)

The MAX4998/MAX14998 provide two digital control
inputs (SEL1, SEL2) to select the signal path between
the COM_ and NO_/NC_ channels. SEL1 selects high-
frequency switching, while SEL2 selects AUX/HPD. On
the MAX4998, switches 1 and 2 are high-frequency

switches and switches 3 and 4 are both low-frequency
switches. On the MAX14998, switches 1, 2, 3, and 4 are
high-frequency switches and switches 5 and 6 are low-
frequency switches. The truth tables for the MAX4998/
MAX14998 are depicted in the Functional Diagrams/
Truth Tables
. Drive SEL_ 0V to V

DD

to minimize power

consumption.

Analog Signal Levels

The MAX4998/MAX14998 accept standard DisplayPort
signals to a maximum of (V

DD

- 1.8V). Signals on the

COM_+ channels are routed to either the NO_+ or NC_+
channels. Signals on the COM_- channels are routed
to either the NO_- or NC_- channels. The MAX4998/
MAX14998 are bidirectional switches, allowing COM_,
NO_, and NC_, to be used as either inputs or outputs.

Pin Description (continued)

PIN

NAME

FUNCTION

MAX4998

MAX14998

23

34

NO0+

Analog Switch 1. Normally Open positive terminal.

24

GND

Ground

25

39

NC1-

Analog Switch 2. Normally Closed negative terminal.

26

40

NC1+

Analog Switch 2. Normally Closed positive terminal.

27

41

NC0-

Analog Switch 1. Normally Closed negative terminal.

28

42

NC0+

Analog Switch 1. Normally Closed positive terminal.

10

COM3-

Analog Switch 4. Common negative terminal.

11

COM4+

Analog Switch 5. Common positive terminal.

12

COM4-

Analog Switch 5. Common negative terminal.

14

COM5+

Analog Switch 6. Common positive terminal.

15

COM5-

Analog Switch 6. Common negative terminal.

18

NO5-

Analog Switch 6. Normally open negative terminal.

19

NO5+

Analog Switch 6. Normally open positive terminal.

20

NO4-

Analog Switch 5. Normally open negative terminal.

21

NO4+

Analog Switch 5. Normally open positive terminal.

22

NC5-

Analog Switch 6. Normally Closed negative terminal.

23

NC5+

Analog Switch 6. Normally Closed positive terminal.

24

NC4-

Analog Switch 5. Normally Closed negative terminal.

25

NC4+

Analog Switch 5. Normally Closed positive terminal.

27

NO3-

Analog Switch 4. Normally Open negative terminal.

35

NC3-

Analog Switch 4. Normally Closed negative terminal.

EP

Exposed Pad. Internally connected to GND. Connect to a large plane to maximize
thermal performance. Not intended as an electrical part.