2 dc electrical characteristics, Dc electrical characteristics, Nuc140 series data sheet – Rainbow Electronics NUC140 User Manual
Page 57

NUC140 Series DATA SHEET
Publication Release Date: May 31, 2010
- 57 -
Revision V1.02
7.2
DC Electrical Characteristics
(VDD-VSS=3.3V, TA = 25
°C, F
OSC
= 50 MHz unless otherwise specified.)
SPECIFICATION
PARAMETER SYM.
MIN. TYP. MAX.
UNI
T
TEST CONDITIONS
Operation voltage
V
DD
2.5 5.5 V
V
DD
=2.5V ~ 5.5V up to 50 MHz
Power Ground
V
SS
AV
SS
-0.3 V
LDO Output Voltage
(bypass = 0)
V
LDO
-10% 2.45 +10%
V V
DD
> 2.7V
LDO Output Voltage
(bypass = 0)
V
LDO
-10% V
DD
+10%
V V
DD
< 2.7V
Analog Operating Voltage
AV
DD
0
V
DD
V
Analog Reference Voltage
Vref
0
AV
DD
V
I
DD1
50 mA
V
DD
= 5.5V@50Mhz,
enable all IP and PLL, XTAL=12MHz
I
DD2
33
mA
V
DD
=5.5V@50Mhz,
disable all IP and enable PLL,
XTAL=12MHz
I
DD3
45
mA
V
DD
= 3V@50Mhz,
enable all IP and PLL, XTAL=12MHz
Operating Current
Normal Run Mode
@ 50Mhz
I
DD4
27
mA
V
DD
= 3V@50Mhz,
disable all IP and enable PLL,
XTAL=12MHz
I
DD5
22 mA
V
DD
= 5.5V@12Mhz,
enable all IP and disable PLL,
XTAL=12MHz
I
DD6
15
mA
V
DD
= 5.5V@12Mhz,
disable all IP and disable PLL,
XTAL=12MHz
I
DD7
20
mA
V
DD
= 3V@12Mhz,
enable all IP and disable PLL,
XTAL=12MHz
Operating Current
Normal Run Mode
@ 12Mhz
I
DD8
12
mA
V
DD
= 3V@12Mhz,
disable all IP and disable PLL,
XTAL=12MHz