9

Pin Description

PIN

MAX6754/
MAX6755/

MAX6756

MAX6757/
MAX6758/

MAX6759

MAX6760/
MAX6761/

MAX6762

MAX6763/

MAX6764

NAME

FUNCTION

1

1

1

Power Voltage Input. V

CC

powers the device. V

CC

is the monitored

voltage.

1

V

CC

Power Input. V

CC

powers the device.

2

2

2

2

GND

Ground

3

3

8

MR

Active-Low Manual Reset Input. Drive MR low to assert undervoltage
and reset outputs. The asserted output remains asserted for the
specified propagation delay period after MR goes high. MR is internally
pulled up to V

CC

through a 26k

Ω resistor.

4

RESET/

RESET

Reset Output. The Reset Output asserts when V

CC

is below the

selected UV

TH

threshold or above the selected OV

TH

threshold. Reset

output deasserts after the specified timeout period after V

CC

rises

above the UV

TH

threshold or drops below the OV

TH

threshold.

MAX6754: Active-low push-pull output (RESET).
MAX6755: Active-high push-pull output (RESET).
MAX6756: Active-low open-drain output (RESET).

5

6

4

SET

Threshold Window Select Input. SET configures the undervoltage and
overvoltage window range for the internal detectors. Connect SET to
GND for ±5% window, or to V

CC

for ±10% window. Bias SET to V

CC

/2

for a ±15% window.

4

6

UV/

UV

Undervoltage Output. UV/UV asserts when the monitored
supply/supplies are below the UV

TH

thresholds or MR is low. UV/UV

deasserts after the specified timeout period when the monitored
supply/supplies rise above the UV

TH

thresholds or for the specified

propagation delay after MR goes high.
MAX6757/MAX6760: Active-low push-pull output (UV).
MAX6758/MAX6761: Active-high push-pull output (UV).
MAX6759/MAX6762: Active-low open-drain output (UV).

3

V

CC2

V

CC2

Voltage Input. Input for the second window voltage monitor, and

device output power supply when V

CC2

> V

CC

.

5

5

5

OV

Active-Low Overvoltage Output. OV asserts low when the monitored
supply/supplies are above their overvoltage threshold (OV

TH

). OV goes

high impedance immediately when the monitored supply/supplies drop
below OV

TH

.

There is no timeout delay period for the OV output.
For MAX6763/MAX6764, OV is low when OVIN is above the internal
0.5V threshold. OV is high when OVIN is below the internal 0.5V
threshold.
MAX6757–MAX6762: Active-low open-drain output.
MAX6763: Active-low push-pull output.
MAX6764: Active-low open-drain output.