beautypg.com

Typical operating circuit chip information – Rainbow Electronics MAX4987BE User Manual

Page 8

background image

MAX4987AE/MAX4987BE

are specified for ±15kV Air-Gap Discharge and ±6kV
Contact Discharge IEC 61000-4-2 on the CD+ and CD-
pins.

The major difference between tests done using the
Human Body Model and IEC 61000-4-2 is a higher peak
current in IEC 61000-4-2, due to lower series resistance.
Hence, the ESD withstand voltage measured to IEC
61000-4-2 generally is lower than that measured using
the Human Body Model. Figure 5 shows the IEC 61000-
4-2 model. The Contact Discharge method connects the
probe to the device before the probe is charged. The
Air-Gap Discharge test involves approaching the device
with a charged probe.

Overvoltage-Protection Controller
with USB ESD Protection

8

_______________________________________________________________________________________

CHARGE-CURRENT-

LIMIT RESISTOR

DISCHARGE

RESISTANCE

STORAGE
CAPACITOR

Cs

150pF

R

C

50M

Ω TO 100MΩ

R

D

330

Ω

HIGH-

VOLTAGE

DC

SOURCE

DEVICE

UNDER

TEST

Figure 5. IEC 61000-4-2 ESD Test Model

OVERCURRENT
FAULT

IN

CD+

CD-

OUT

V

CC

CHARGE

PUMP

CONTROL

LOGIC

MAX4987AE/

MAX4987BE

ACOK

V

IO

PHONE

LOAD

V

BG

REFERENCE

+

-

+

-

OV

UV

EN

USB

CONNECTOR

VBUS

D+

D-

USB

TRANSCEIVER

V

CC

D+

D-

GND

V

CC

BATTERY

CHARGER

Typical Operating Circuit

Chip Information

PROCESS: BiCMOS