Typical operating characteristics, Electrical characteristics (continued) – Rainbow Electronics MAX6508 User Manual
Page 3
MAX6505–MAX6508
Dual Trip SOT Temperature Switches
_______________________________________________________________________________________
3
20
30
25
40
35
45
50
-40
-10 5
20
-25
35 50 65 80 95 110 125
SUPPLY CURRENT
vs. TEMPERATURE
MAX6505/8-01
TEMPERATURE (
°C)
SUPPLY CURRENT (µA)
V
CC
= +5V
R
PULLUP
= 100k
Ω
0.5
1.0
1.5
2.0
2.5
-40
-10 5
-25
20 35 50 65 80 95 110 125
HYSTERESIS vs. TRIP TEMPERATURE
MAX6505/8-02
TEMPERATURE (
°C)
HYSTERESIS (
°C)
V
CC
= +5V
R
PULLUP
= 100k
Ω
-0.8
-0.6
-0.7
-0.3
-0.4
-0.5
0
-0.1
-0.2
0.1
2.5
3.5
3.0
4.0
4.5
5.0
5.5
TRIP-POINT ERROR (%)
vs. SUPPLY VOLTAGE
MAX6505/8-03
SUPPLY VOLTAGE (V)
TRIP-POINT ERROR (%)
NORMALIZED TO TRIP-POINT
TEMPERATURE AT V
CC
= +5V
MAX6505
STARTUP AND POWER-DOWN
(T < T
TH
)
MAX6505/8-04
A
B
A: V
CC
PULSE
B: ALARM VOLTAGE, R
PULLUP
= 100k
Ω
100µs/div
2V/div
MAX6505
STARTUP DELAY
(T > T
TH
)
MAX6505/8-05
A
B
A: V
CC
PULSE
B: ALARM VOLTAGE, R
PULLUP
= 100k
Ω
100µs/div
2V/div
Typical Operating Characteristics
(V
CC
= +5V, unless otherwise noted.)
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +2.5V to +5.5V, R
PULLUP
= 100k
Ω (MAX6505/MAX6507 only), T
A
= -40°C to +125°C, unless otherwise noted. Typical values
are at T
A
= +25°C and V
CC
= +5V, unless otherwise noted.) (Note 1)
Note 1: 100% production tested at T
A
= +25°C. Specifications over temperature limits are guaranteed by design.
Note 2: T
ALARM
, T
UNDER
, and T
OVER
are factory-programmed temperature trip thresholds from -40°C to +125°C in 5°C increments.
Note 3: Temperature threshold hysteresis is defined as the difference from positive-going temperature thresholds minus the nega-
tive-going temperature thresholds.
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
V
CC
= 5.5V, V
ALARM
= 5.5V,
V
WARN
= 5.5V (MAX6505)
1
Open-Drain Output Leakage
Current
V
CC
= 5.5V, V
OK
= 5.5V,
V
OVER
= 5.5V (MAX6507)
1
µA