beautypg.com

Model 6700 downflow, Control operation, Page 6 – Peerless Water 6700 - Service Manual User Manual

Page 6

background image

Printed in U.S.A.

Page 6

MODEL 6700 Downflow

Control Operation

Normal Control Operation

Flow Meter Equipped Delayed Regeneration Valves

In Normal Operation the Time Of Day Display will alternate being viewed with the Volume Remaining Display. Water
flow through the unit is indicated by the Meter Arrow that will flash in a direct relationship to flow rate. As treated water
is used, the Volume Remaining Display will count down from a maximum value to the calculated reserve capacity. Once
this occurs, the Reserve Arrow will begin to flash as an indication that reserve capacity is being used. At the preset
Regeneration Time a regeneration cycle will then be initiated immediately.

Volume Remaining Display Indicator

Time of Day Display Indicator

Service Indicator:

Valve In Service

- Arrow On

Manual Regeneration Tonight - Flashing Arrow

Reserve Indicator:

Volume Remaining Above Reserve

- Arrow Off

Volume Remaining At Or Below Reserve

- Arrow Flashing

Regeneration Indicator:

Valve In Regeneration - Arrow On

Flow Indicator:

Arrow Flashes With Water Flow

Lockout Indicator:

Lockout Signal - Arrow On

Sensor Indicator:

Sensor Input Signal

- Flashing Arrow

Valid Regeneration Signal

- Arrow On

For Example:
235 Gallons Of Water Remaining
(Valve in Service)
(No Water flow)
(Volume is below reserve capacity)

For Example:
0 Gallons Of Water Remaining
(Valve in Service)
(Water flowing, Meter Arrow flashing)
(Volume is below reserve capacity)