5. Assembling Sidewall Sheets

PNEG-4021 40 Series 18', 21' and 24' Diameter Bins

33

Caulking Detail for Standard (Non-Laminated) Sheets

To keep out moisture from overlapping the sheets, it is necessary to apply caulk to each sheet prior
to installing.

NOTE: Always assemble the sidewall sheets with the overlap in the same direction.

1. Apply a strip of caulk near the outside edge of the outer sheet and between the outer two (2) rows

of bolts (A), then apply a strip of caulk 10" (25.4 cm) long along the horizontal seams (B), as shown
in

Figure 5A

.

Figure 5A Standard and Quad Punched Sidewall Sheets as Viewed from the Outside

2. Before bolting the next ring into place, apply one 10" strip of caulk (C) on the front of the underlapped

sheet at each joint.

3. Also, place a 10" (25.4 cm) strip of caulk (D) along the lower horizontal edge of the lapping

sheet at every vertical seam. This will fill the space that occurs between the holes caused by the
overlapping sheets.

(See Figure 5B on Page 34.)

Ref #

Description

A

Vertical Strip of Caulk

B

10" (25.4 cm) Horizontal Strip of Caulk